Neni to HP Proliant DL120 G5 ??? Ci sitovka
bge0: <HP NC105i PCIe Gigabit Server Adapter, ASIC rev. 0x00a200> mem
0xed000000-0xed00ffff irq 17 at device 0.0 on pci14
???
Pozoruju to same pri zvysenych tocich na danem serveru oproti Ciscu 2950 :
Stava se to pri zalohach {15 giga} prenosem na backup server.
bge0: watchdog timeout -- resetting
bge0: link state changed to DOWN
bge0: link state changed to UP
bge0: watchdog timeout -- resetting
bge0: link state changed to DOWN
bge0: link state changed to UP
bge0: watchdog timeout -- resetting
bge0: link state changed to DOWN
bge0: link state changed to UP
Mam tam jeste v PCI-X Intela na tom samem zeleze a ten drzi v pohode.
f.
On Apr 22, 2011, at 7:30 PM, Gabriel wrote:
> Povedlo se mi dostat do servrovny a presouvat nejake vetsi soubory (radove
> desitky GB) - problem je tedy na interni broadcom sitovce, ktera spojuje
> webserver a nfs server, hlasilo to watchdog timeout - resetting a pak se to
> samo otocilo. Tohle se mi za celou noc povedlo tak 3x.
>
> Kazdopadne nasel jsem na netu, ze by mohlo pomoct nastaveni
> hw.bge.allow_asf="1" do /boot/loader.conf, tak jsem zvedav.
>
> G
> --
> FreeBSD mailing list ([email protected])
> http://www.freebsd.cz/listserv/listinfo/users-l
--
S pozdravem / Best regards
Filip Huška
Technický ředitel / CTO
==========================
COOLHOUSING The best for your server!
==========================
Vinohradská 190, Praha 3
http://www.coolhousing.net mail:
[email protected]
TEL: +420 777 3100 00
Sent from POSIX system - no viruses, spam etc.
--
FreeBSD mailing list ([email protected])
http://www.freebsd.cz/listserv/listinfo/users-l