Did you try removing both startupMaxConnectAttempts and maxConnectAttempts? >From memory, I believe maxConnectAttempts will be used if startupMaxConnectAttempts isn't set, so removing startupMaxConnectAttempts by itself wouldn't be expected to solve the problem.
Tim On Sun, Dec 16, 2018, 3:31 AM BlueSpirit <adityaguptakan...@gmail.com wrote: > Tim Bain wrote > > Your use of maxReconnectAttempts=2 seems inconsistent with your stated > > goal > > of being able to connect to a broker that's not available when the > > connection factory is created. What are you trying to accomplish with > that > > setting, and if you remove it do you get the expected behavior? > > > > Tim > > > > On Fri, Dec 14, 2018, 7:09 AM Timothy Bish < > > > tabish121@ > > > wrote: > > > > > On 12/14/18 4:54 AM, BlueSpirit wrote: > >> > TL;DR > >> > I would like to instantiate the connection factory even when the > broker > >> is > >> > down. How should I achieve this? > >> > > >> > I am creating a ActiveMQConnectionFactory using the following URL: > >> > > >> > failover:(tcp://localhost:61616)?jms.warnAboutUnstartedConnectionTimeout=30000&initialReconnectDelay=2000&maxReconnectAttempts=2&maxReconnectDelay=2000&startupMaxReconnectAttempts=1 > >> > > >> > The connectionfactory object is not created if the broker is down at > >> the > >> > time of creation. > >> > > >> > As I understand the failover mechanism helps in scenarios when the > >> > connection factory is already created and the ActiveMQ server is > >> restarted. > >> > > >> > > >> > > >> > > >> > > >> > -- > >> > Sent from: > >> http://activemq.2283324.n4.nabble.com/ActiveMQ-User-f2341805.html > >> > > >> What error do you receive when trying to create the factory? You need > >> to provide more information here to make it clear what is happening. > >> > >> -- > >> Tim Bish > >> > >> > > > It shows error as: JMSException. Could not connect after trying 2 times. > Removing starupmaxreconnet doesn't improve. > I want to silently catch this error. > My spring container fails to initialize because the broker is down and > connectionfactory does not initialize. > > Based on my config, if the broker is down after the app is up, and later > restarted, the receiver again connects automatically and starts working. I > would like to get in this state at the time I am loading my app(broker is > down at this moment, but will start later) > > > > > -- > Sent from: > http://activemq.2283324.n4.nabble.com/ActiveMQ-User-f2341805.html >