Hi Edward, You can disable the health checks as advised by Nicolas.
Additionally worth checking, this could be because of stale VR status on Management Server's database. You can also try to rerun a health check on that router from the UI or the API to update the results. ( https://cloudstack.apache.org/api/apidocs-4.14/apis/getRouterHealthCheckResults.html ) Basic tests succeeding could also mean that your global setting is triggering advanced results which has some test failing. Maybe check if Management Server is running basic or advanced checks? 3rd option can be that you can exclude the test that is flaky and failing using "health.checks.to.exclude". ( https://www.shapeblue.com/cloudstack-feature-first-look-vr-health-checks/). Hope it helps. Regards, Anurag On Fri, Jan 22, 2021 at 7:44 AM Edward St Pierre <edward.stpie...@gmail.com> wrote: > Hi, > > Thanks for that Nicolas. > Is that option available on a per VR basis as I have only seen it as a > global option? > > Ed > > On Fri, 22 Jan 2021 at 14:31, Nicolas Vazquez > <nicolas.vazq...@shapeblue.com.invalid> wrote: > > > Hi Edward, > > > > You can disable the health checks by setting > > 'router.health.checks.enabled' to false. > > > > > > Regards, > > > > Nicolas Vazquez > > > > ________________________________ > > From: Edward St Pierre <edward.stpie...@gmail.com> > > Sent: Friday, January 22, 2021 11:25 AM > > To: users@cloudstack.apache.org <users@cloudstack.apache.org> > > Subject: Health Checks for redundant VR or a VPC Router > > > > Hi, > > > > I have recently updated to version 4.15 from 4.13 and it looks great, > > however I seem to have hit a problem with all the alerts filling up with > > the following error: > > > > Health checks failed: 1 failing checks on router > > 342ebf56-4128-4350-967f-cea40c26b080 > > > > For pretty most of my redundant VR or VPC routers. > > > > I have logged directly onto these and have manually run the monitoring > > script with the following output: > > > > root@r-41-VM:~# /usr/bin/python /root/monitorServices.py basic > > monitoring started > > No config items provided - means a redundant VR or a VPC Router > > > > I cannot seem to find a setting that will disable monitoring for this > > subset of device types. Can anyone provide any advice on this? > > > > Ed > > > > nicolas.vazq...@shapeblue.com > > www.shapeblue.com > > 3 London Bridge Street, 3rd floor, News Building, London SE1 9SGUK > > @shapeblue > > > > > > > > >