Yes, the message is self-explanatory:

Unable to find distributed vSwitch dvSwitch0

and you said you are not having dvSwitch0 in your DC- so this does indeed
comes from some TRAFFIC LABEL - so please check your traffic labels for
management and storage and public traffic (guest not being important as
SSVM is attached to only those other 3 networks)

Best,

On Wed, 12 May 2021 at 20:29, Corey, Mike <mike.co...@sap.com.invalid>
wrote:

> Hi again,
>
>
>
> When I enable the zone my system vms just continue to cycle through a
> deployment and expunge.  Only thing I can find in the logs to hint at an
> issue is the line below regarding capacity.  I don’t understand how I can
> have insufficient resources…these are 2 Gen 10 blades with (2) 24 core cpus
> and 764GB memory.
>
>
>
> Is there a setting I need to adjust or something else I should be looking
> for in the logs as an indication as to why they are failing?
>
>
>
> 2021-05-12 12:05:30,769 WARN  [o.a.c.s.SecondaryStorageManagerImpl]
> (secstorage-1:ctx-dfe12939) (logid:61e5d345) Exception while trying to
> start secondary storage vm
>
> com.cloud.exception.InsufficientServerCapacityException: Unable to create
> a deployment for VM[SecondaryStorageVm|s-14-VM]Scope=interface
> com.cloud.dc.DataCenter; id=1
>
>
>
>
>
> Another error I’m seeing is regarding the distributed vSwitch – I setup
> three physical networks – management, storage, guest – each with their own
> VDS “traffic label”.  (example: vds2-phl-csm02-nfs,0,vmwaredvs).
>
>
>
> I don’t have a distributed vSwitch named dvSwitch0 so if ACS is looking
> for that I don’t know why or why it isn’t looking for the switch names I
> have configured under the “traffic label”.
>
>
>
> Line 71606: com.cloud.exception.InsufficientServerCapacityException:
> Unable to create a deployment for
> VM[SecondaryStorageVm|s-26-VM]Scope=interface com.cloud.dc.DataCenter; id=1
>
>             Line 71638:
> com.cloud.exception.InsufficientServerCapacityException: Unable to create a
> deployment for VM[SecondaryStorageVm|s-26-VM]Scope=interface
> com.cloud.dc.DataCenter; id=1
>
>             Line 71660: 2021-05-12 14:15:47,330 INFO
> [o.a.c.s.SecondaryStorageManagerImpl] (secstorage-1:ctx-433a9990)
> (logid:64b260ab) Unable to start secondary storage vm for standby capacity,
> vm id : 26, will recycle it and start a new one
>
>             Line 71722: 2021-05-12 14:15:49,045 ERROR
> [c.c.h.v.m.HypervisorHostHelper] (DirectAgent-12:ctx-69b57f06
> usphlmvesxt01.phl.global.corp.sap, job-112/job-119, cmd: StartCommand)
> (logid:a5237296) Unable to find distributed vSwitch dvSwitch0
>
>             Line 71723: 2021-05-12 14:15:49,045 INFO
> [c.c.h.v.u.VmwareHelper] (DirectAgent-12:ctx-69b57f06
> usphlmvesxt01.phl.global.corp.sap, job-112/job-119, cmd: StartCommand)
> (logid:a5237296) [ignored]failed to get message for exception: Unable to
> find distributed vSwitch dvSwitch0
>
>             Line 71725: Message: Unable to find distributed vSwitch
> dvSwitch0
>
>             Line 71727: java.lang.Exception: Unable to find distributed
> vSwitch dvSwitch0
>
>             Line 71747: Message: Unable to find distributed vSwitch
> dvSwitch0
>
>             Line 71751: 2021-05-12 14:15:49,053 INFO
> [c.c.v.VirtualMachineManagerImpl] (Work-Job-Executor-7:ctx-81037bca
> job-112/job-119 ctx-43bfb160) (logid:a5237296) Unable to start VM on
> Host[-2-Routing] due to StartCommand failed due to Exception:
> java.lang.Exception
>
>             Line 71752: Message: Unable to find distributed vSwitch
> dvSwitch0
>
>
>
>
>
>
>
>
>
>
>
> *Mike Corey*
>
>
> Technology Senior Consultant, IT CS CTW Operation & Virtualization Service
> US
>
>
> *SAP AMERICA, INC.* 3999 West Chester Pike, Newtown Square, 19073 United
> States
>
>
> T +1 610 661 0905, M +1 484 274 2658, E mike.co...@sap.com
>
>
>
>
>
>
>


-- 

Andrija Panić