24.08.2015 12:35, Tom Yates пишет:
I've got a failover firewall pair where the external interface is ADSL; that is, PPPoE. i've defined the service thus:primitive ExternalIP lsb:hb-adsl-helper \ op monitor interval="60s" and in addition written a noddy script /etc/init.d/hb-adsl-helper, thus: #!/bin/bash RETVAL=0 start() { /sbin/pppoe-start } stop() { /sbin/pppoe-stop } case "$1" in start) start ;; stop) stop ;; status) /sbin/ifconfig ppp0 >& /dev/null && exit 0 exit 1 ;; *) echo $"Usage: $0 {start|stop|status}" exit 3 esac exit $? The problem is that sometimes the ADSL connection falls over, as they do, eg: Aug 20 11:42:10 positron pppd[2469]: LCP terminated by peer Aug 20 11:42:10 positron pppd[2469]: Connect time 8619.4 minutes. Aug 20 11:42:10 positron pppd[2469]: Sent 1342528799 bytes, received 164420300 bytes. Aug 20 11:42:13 positron pppd[2469]: Connection terminated. Aug 20 11:42:13 positron pppd[2469]: Modem hangup Aug 20 11:42:13 positron pppoe[2470]: read (asyncReadFromPPP): Session 1735: Input/output error Aug 20 11:42:13 positron pppoe[2470]: Sent PADT Aug 20 11:42:13 positron pppd[2469]: Exit. Aug 20 11:42:13 positron pppoe-connect: PPPoE connection lost; attempting re-connection. CRMd then logs a bunch of stuff, followed by Aug 20 11:42:18 positron lrmd: [1760]: info: rsc:ExternalIP:8: stop Aug 20 11:42:18 positron lrmd: [28357]: WARN: For LSB init script, no additional parameters are needed. [...] Aug 20 11:42:18 positron pppoe-stop: Killing pppd Aug 20 11:42:18 positron pppoe-stop: Killing pppoe-connect Aug 20 11:42:18 positron lrmd: [1760]: WARN: Managed ExternalIP:stop process 28357 exited with return code 1. At this point, the PPPoE connection is down, and stays down. CRMd doesn't fail the group which contains both internal and external interfaces over to the other node, but nor does it try to restart the service. I'm fairly sure this is because I've done something boneheaded, but I can't get my bone head around what it might be. Any light anyone can shed is much appreciated.
If stop operation failed resource state is undefined; pacemaker won't do anything with this resource. Either make sure script returns success when appropriate or the only option is to make it fence node where resource was active.
_______________________________________________ Users mailing list: [email protected] http://clusterlabs.org/mailman/listinfo/users Project Home: http://www.clusterlabs.org Getting started: http://www.clusterlabs.org/doc/Cluster_from_Scratch.pdf Bugs: http://bugs.clusterlabs.org