On 27/09/15 16:06, Digimer wrote:
On 27/09/15 11:02 AM, Alex Crow wrote:

On 27/09/15 15:54, Digimer wrote:
On 27/09/15 10:40 AM, Alex Crow wrote:
Hi List,

I'm trying to set up a failover iSCSI storage system for oVirt using a
self-hosted engine. I've set up DRBD in Master-Slave for two iSCSI
targets, one for the self-hosted engine and one for the VMs. I has this
all working perfectly, then after trying to move the engine's LUN to the
opposite host, all hell broke loose. The VMS LUN is still fine, starts
I'm guessing no fencing?
Hi Digimer,

No, but I've tried turning off one machine and still no success as a
single node :-(
You *must* have working fencing, anyway. So now strikes me as a
fantastic time to add it. Turning off the node alone doesn't help.


I did a pcs stonith confirm after sending magic-sysrq-b to glenrock and it looks like it's up now, cheers very much!

I do have some APC power bars, but they are APC-rebranded Schneider kit, which is frankly awful, not at all as good as the old APC stuff. BTW avoid APC KVMs like the plague, they seriously suck - hanging all the time, refuse to allow a console view from any other than the same network range they are on, the list is huge. Support is also dire.

I might have to use the fallback of IPMI but it don't like it as much as I've seen IPMI cards hang too.....

I think a remote controlled robot that can physically pull out power cables would be great!

Thanks

Alex



_______________________________________________
Users mailing list: [email protected]
http://clusterlabs.org/mailman/listinfo/users

Project Home: http://www.clusterlabs.org
Getting started: http://www.clusterlabs.org/doc/Cluster_from_Scratch.pdf
Bugs: http://bugs.clusterlabs.org

Reply via email to