>>> Ken Gaillot <[email protected]> schrieb am 18.10.2016 um 17:07 in >>> Nachricht <[email protected]>: > On 10/14/2016 03:22 PM, Anne Nicolas wrote:
[...] >> cluster logs are flooded by : >> Oct 14 17:42:28 [3445] bzvairsvr attrd: notice: >> attrd_trigger_update: Sending flush op to all hosts for: >> master-drbdserv (10000) >> Oct 14 17:42:28 [3445] bzvairsvr attrd: notice: >> attrd_perform_update: Sent update master-drbdserv=10000 failed: >> Transport endpoint is not connected > > This is strange, and the cause of the problem. A master/slave resource > agent will try to set node attributes indicating which node should > become the master. Here, we see that this is failing -- it appears attrd > (Pacemaker's node attribute daemon) is unable to talk to any other daemons. > > I'm not sure why this would happen, especially if the rest of the > daemons do not have a problem talking to each other. But that's where > you need to investigate. >From my little experience it's a bad idea to route I/O traffic and cluster >communication over the same link: We had cases where cluster communication >(especially when using SCTP) showed errors when traffic was high. Maybe that >applies... > > One thing I would say is that 1.1.8 is really old at this point, which > means you're using the "legacy" attrd, which I'm not very familiar with. I agree: Even SLES11 SP4 uses old software, but it's at "pacemaker-1.1.12-13.1" at least. Things _really_ got better with later releases. [...] Regards, Ulrich _______________________________________________ Users mailing list: [email protected] http://clusterlabs.org/mailman/listinfo/users Project Home: http://www.clusterlabs.org Getting started: http://www.clusterlabs.org/doc/Cluster_from_Scratch.pdf Bugs: http://bugs.clusterlabs.org