Hi All,

I have created active/passive pacemaker cluster on RHEL 7.

here is my environment:
clustera : 192.168.11.1
clusterb : 192.168.11.2
clustera-ilo4 : 192.168.11.10
clusterb-ilo4 : 192.168.11.11

both nodes are connected SAN storage for shared storage.

i used the following cmd to create my stonith devices on each node :
# pcs -f stonith_cfg stonith create ipmi-fence-node1 fence_ipmilan parms
lanplus="ture" pcmk_host_list="clustera" pcmk_host_check="static-list"
action="reboot" ipaddr="192.168.11.10" login=adminsitrator passwd=1234322
op monitor interval=60s

# pcs -f stonith_cfg stonith create ipmi-fence-node02 fence_ipmilan parms
lanplus="true" pcmk_host_list="clusterb" pcmk_host_check="static-list"
action="reboot" ipaddr="192.168.11.11" login=USERID passwd=password op
monitor interval=60s

# pcs status
ipmi-fence-node1                     clustera
ipmi-fence-node2                     clusterb

but when i failover to passive node, then i ran
# pcs status

ipmi-fence-node1                    clusterb
ipmi-fence-node2                    clusterb

why both fence device locate on the same node ?


-- 
Kind regards,
Albert Weng

<https://www.avast.com/sig-email?utm_medium=email&utm_source=link&utm_campaign=sig-email&utm_content=webmail>
不含病毒。www.avast.com
<https://www.avast.com/sig-email?utm_medium=email&utm_source=link&utm_campaign=sig-email&utm_content=webmail>
<#DAB4FAD8-2DD7-40BB-A1B8-4E2AA1F9FDF2>
_______________________________________________
Users mailing list: [email protected]
http://lists.clusterlabs.org/mailman/listinfo/users

Project Home: http://www.clusterlabs.org
Getting started: http://www.clusterlabs.org/doc/Cluster_from_Scratch.pdf
Bugs: http://bugs.clusterlabs.org

Reply via email to