----- On May 17, 2017, at 2:11 PM, Vladislav Bogdanov [email protected] wrote:
> 08.05.2017 22:20, Lentes, Bernd wrote: >> Hi, >> >> i remember that digimer often campaigns for a fence delay in a 2-node >> cluster. >> E.g. here: >> http://oss.clusterlabs.org/pipermail/pacemaker/2013-July/019228.html >> In my eyes it makes sense, so i try to establish that. I have two HP servers, >> each with an ILO card. >> I have to use the stonith:external/ipmi agent, the stonith:external/riloe >> refused to work. >> >> But i don't have a delay parameter there. >> crm ra info stonith:external/ipmi: > > Hi, > > There is another ipmi fence agent - fence_ipmilan (part of fence-agents > package). It has 'delay' parameter. > >> I don't see that. crm(live)# ra info stonith:ipmilan IPMI Over LAN (stonith:ipmilan) IPMI LAN STONITH device Parameters (*: required, []: default): hostname* (string): The hostname of the STONITH device ipaddr* (string): IP Address The IP address of the STONITH device port* (string): The port number to where the IPMI message is sent auth* (string): The authorization type of the IPMI session ("none", "straight", "md2", or "md5") priv* (string): The privilege level of the user ("operator" or "admin") login* (string): Login The username used for logging in to the STONITH device password* (string): Password The password used for logging in to the STONITH device priority (integer, [0]): The priority of the stonith resource. Devices are tried in order of highest priority to lowest. pcmk_host_argument (string, [port]): Advanced use only: An alternate parameter to supply instead of 'port' Some devices do not support the standard 'port' parameter or may provide additional ones. Use this to specify an alternate, device-specific, parameter that should indicate the machine to be fenced. A value of 'none' can be used to tell the cluster not to supply any additional parameters. pcmk_host_map (string): A mapping of host names to ports numbers for devices that do not support host names. Eg. node1:1;node2:2,3 would tell the cluster to use port 1 for node1 and ports 2 and 3 for node2 pcmk_host_list (string): A list of machines controlled by this device (Optional unless pcmk_host_check=static-list). pcmk_host_check (string, [dynamic-list]): How to determine which machines are controlled by the device. Allowed values: dynamic-list (query the device), static-list (check the pcmk_host_list attribute), none (assume every device can fence every machine) ... There is no delay parameter, and all the pcmk_*** parameters are the ones from stonithd, and that one does not have a dedicated delay parameter, just the pcmk_delay_max parameter which is not fixed but random. Do you have another ipmilan RA ? I have SLES 11 SP4 boxes, maybe my RA is not recent enough ? Bernd Helmholtz Zentrum Muenchen Deutsches Forschungszentrum fuer Gesundheit und Umwelt (GmbH) Ingolstaedter Landstr. 1 85764 Neuherberg www.helmholtz-muenchen.de Aufsichtsratsvorsitzende: MinDir'in Baerbel Brumme-Bothe Geschaeftsfuehrer: Prof. Dr. Guenther Wess, Heinrich Bassler, Dr. Alfons Enhsen Registergericht: Amtsgericht Muenchen HRB 6466 USt-IdNr: DE 129521671 _______________________________________________ Users mailing list: [email protected] http://lists.clusterlabs.org/mailman/listinfo/users Project Home: http://www.clusterlabs.org Getting started: http://www.clusterlabs.org/doc/Cluster_from_Scratch.pdf Bugs: http://bugs.clusterlabs.org