HI,

i have a two node cluster running on SLES 12 SP4.
I did some testing on it.
I put one into standby (ha-idg-2), the other (ha-idg-1) got fenced a few 
minutes later because i made a mistake.
ha-idg-2 was DC. ha-idg-1 made a fresh boot and i started corosync/pacemaker on 
it.
It seems ha-idg-1 didn't find the DC after starting cluster and some sec later 
elected itself  to the DC, 
afterwards fenced ha-idg-2.

Oct 09 18:04:43 [9550] ha-idg-1 corosync notice  [MAIN  ] Corosync Cluster 
Engine ('2.3.6'): started and ready to provide service.
Oct 09 18:04:43 [9550] ha-idg-1 corosync info    [MAIN  ] Corosync built-in 
features: debug testagents augeas systemd pie relro bindnow
Oct 09 18:04:43 [9550] ha-idg-1 corosync notice  [TOTEM ] Initializing 
transport (UDP/IP Multicast).
Oct 09 18:04:43 [9550] ha-idg-1 corosync notice  [TOTEM ] Initializing 
transmit/receive security (NSS) crypto: aes256 hash: sha1
Oct 09 18:04:43 [9550] ha-idg-1 corosync notice  [TOTEM ] The network interface 
[192.168.100.10] is now up.

Oct 09 18:05:06 [9565] ha-idg-1       crmd:     info: crm_timer_popped: 
Election Trigger (I_DC_TIMEOUT) just popped (20000ms)
Oct 09 18:05:06 [9565] ha-idg-1       crmd:  warning: do_log:   Input 
I_DC_TIMEOUT received in state S_PENDING from crm_timer_popped
Oct 09 18:05:06 [9565] ha-idg-1       crmd:     info: do_state_transition:      
State transition S_PENDING -> S_ELECTION | input=I_DC_TIMEOUT 
cause=C_TIMER_POPPED origin=crm_timer_popped
Oct 09 18:05:06 [9565] ha-idg-1       crmd:     info: election_check:   
election-DC won by local node
Oct 09 18:05:06 [9565] ha-idg-1       crmd:     info: do_log:   Input 
I_ELECTION_DC received in state S_ELECTION from election_win_cb
Oct 09 18:05:06 [9565] ha-idg-1       crmd:   notice: do_state_transition:      
State transition S_ELECTION -> S_INTEGRATION | input=I_ELECTION_DC 
cause=C_FSA_INTERNAL origin=election_win_cb
Oct 09 18:05:06 [9565] ha-idg-1       crmd:     info: do_te_control:    
Registering TE UUID: f302e1d4-a1aa-4a3e-b9dd-71bd17047f82
Oct 09 18:05:06 [9565] ha-idg-1       crmd:     info: set_graph_functions:      
Setting custom graph functions
Oct 09 18:05:06 [9565] ha-idg-1       crmd:     info: do_dc_takeover:   Taking 
over DC status for this partition

Oct 09 18:05:07 [9564] ha-idg-1    pengine:  warning: stage6:   Scheduling Node 
ha-idg-2 for STONITH
Oct 09 18:05:07 [9564] ha-idg-1    pengine:   notice: LogNodeActions:    * 
Fence (Off) ha-idg-2 'node is unclean'

Is my understanding correct ?


In the log of ha-idg-2 i don't find anything for this period:

Oct 09 17:58:46 [12504] ha-idg-2 stonith-ng:     info: cib_device_update:       
Device fence_ilo_ha-idg-2 has been disabled on ha-idg-2: score=-10000
Oct 09 17:58:51 [12503] ha-idg-2        cib:     info: cib_process_ping:        
Reporting our current digest to ha-idg-2: 59c4cfb14defeafbeb3417e222242cd9 for 
2.9506.36 (0x242b110 0)

Oct 09 18:00:42 [12508] ha-idg-2       crmd:     info: throttle_send_command:   
New throttle mode: 0001 (was 0000)
Oct 09 18:01:12 [12508] ha-idg-2       crmd:     info: 
throttle_check_thresholds:       Moderate CPU load detected: 32.220001
Oct 09 18:01:12 [12508] ha-idg-2       crmd:     info: throttle_send_command:   
New throttle mode: 0010 (was 0001)
Oct 09 18:01:42 [12508] ha-idg-2       crmd:     info: throttle_send_command:   
New throttle mode: 0001 (was 0010)
Oct 09 18:02:42 [12508] ha-idg-2       crmd:     info: throttle_send_command:   
New throttle mode: 0000 (was 0001)

ha-idg-2 is fenced and after a reboot i started corosync/pacmeaker on it again:

Oct 09 18:29:05 [11795] ha-idg-2 corosync notice  [MAIN  ] Corosync Cluster 
Engine ('2.3.6'): started and ready to provide service.
Oct 09 18:29:05 [11795] ha-idg-2 corosync info    [MAIN  ] Corosync built-in 
features: debug testagents augeas systemd pie relro bindnow
Oct 09 18:29:05 [11795] ha-idg-2 corosync notice  [TOTEM ] Initializing 
transport (UDP/IP Multicast).
Oct 09 18:29:05 [11795] ha-idg-2 corosync notice  [TOTEM ] Initializing 
transmit/receive security (NSS) crypto: aes256 hash: sha1

What is the meaning of the lines with the throttle ?

Thanks.


Bernd

-- 

Bernd Lentes 
Systemadministration 
Institut für Entwicklungsgenetik 
Gebäude 35.34 - Raum 208 
HelmholtzZentrum münchen 
[email protected] 
phone: +49 89 3187 1241 
phone: +49 89 3187 3827 
fax: +49 89 3187 2294 
http://www.helmholtz-muenchen.de/idg 

Perfekt ist wer keine Fehler macht 
Also sind Tote perfekt
 

Helmholtz Zentrum Muenchen
Deutsches Forschungszentrum fuer Gesundheit und Umwelt (GmbH)
Ingolstaedter Landstr. 1
85764 Neuherberg
www.helmholtz-muenchen.de
Aufsichtsratsvorsitzende: MinDir'in Prof. Dr. Veronika von Messling
Geschaeftsfuehrung: Prof. Dr. med. Dr. h.c. Matthias Tschoep, Kerstin Guenther
Registergericht: Amtsgericht Muenchen HRB 6466
USt-IdNr: DE 129521671

_______________________________________________
Manage your subscription:
https://lists.clusterlabs.org/mailman/listinfo/users

ClusterLabs home: https://www.clusterlabs.org/

Reply via email to