21.08.2020 21:16, Ken Gaillot пишет:
> 
> Previously at shutdown, sbd determined a clean pacemaker shutdown by
> checking whether any resources were running at shutdown. This would
> lead to sbd fencing if pacemaker shut down in maintenance mode with
> resources active.


What conditions lead to it? I tried to reproduce it, but so far I was
able to set node in maintenance mode and stop pacemaker on it without
any ill effects. This is openSUSE Tumebleweed with sbd at commit
4b617a1b8f16033ac464cf2d562f0646082c40fa.