Hi all
I am facing a wierd situation when i start testpmd app inside two VMs( Case 3 ).
Please see the following setup.
Hardware Information
System
Dell Inc. PowerEdge R630
?
?
BIOS
Dell Inc. version1.0.4
?
CPU
Intel(R) Xeon(R) x86_64 E5-2630 v3 2.40 Ghz
?
Processor(s): 16
?
?
Cache: 20480 KB
?
?
?
Memory
Size: 16 GB*6
?
?
?
?
Type: DDR4
?
?
Speed: 2133MHz
?
?
?
Ethernet Controller
Intel Corporation Ethernet 10G 2P X520 Adapter *2
Software information
Qemu = qemu-2.5.1.1
DPDK = dpdk-2.2.0
OVS = ovs-branch-2.5
Input stream : 10Gbps(5G with vlan 1001 and 5G with vlan 1002) which is
generated by Spirent testcenter
| VM1 | | VM2 |
?1001? ?1002?
-----------------------
| OVS |
-----------------------
? ?
-----------------------
TestCenter |
-----------------------
ovs setup:
modprobe openvswitch
rm -rf /usr/local/var/run/openvswitch/*
rm -rf /opt/ovs-vswitchd.log
modprobe uio
insmod $DPDK_BUILD/kmod/igb_uio.ko
$DPDK_DIR/tools/dpdk_nic_bind.py --bind=igb_uio p3p1
$DPDK_DIR/tools/dpdk_nic_bind.py --bind=igb_uio p3p2
$DPDK_DIR/tools/dpdk_nic_bind.py --status
rm /usr/local/etc/openvswitch/conf.db -rf
mkdir -p /usr/local/etc/openvswitch
mkdir -p /usr/local/var/run/openvswitch
cd $OVS_DIR
./ovsdb/ovsdb-tool create /usr/local/etc/openvswitch/conf.db
./vswitchd/vswitch.ovsschema
./ovsdb/ovsdb-server --remote=punix:/usr/local/var/run/openvswitch/db.sock
--remote=db:Open_vSwitch,Open_vSwitch,manager_options
--private-key=db:Open_vSwitch,SSL,private_key
--certificate=db:Open_vSwitch,SSL,certificate
--bootstrap-ca-cert=db:Open_vSwitch,SSL,ca_cert --pidfile --detach
./utilities/ovs-vsctl --no-wait init
./utilities/ovs-vsctl --no-wait set Open_vSwitch . other_config:dpdk-init=true
./vswitchd/ovs-vswitchd --dpdk --socket-mem 4096,4096 -n 4 --
unix:/usr/local/var/run/openvswitch/db.sock --log-file=$OVS_LOG --pidfile
--detach
Case 1:
VM1 start testpmd, fwd = iofwd
VM2 start testpmd,fwd = iofwd
Result = Spirent testcenter show output stream is reaching line speed 10G.
Case 2:
VM1 testpmd = started, fwd = iofwd
VM2 testpmd=stopped,fwd = none
Result = Spirent testcenter show output stream is reaching 5G.
Which is reasonable.
Case 3:
VM1 testpmd = started, fwd = iofwd
VM2 testpmd = started ,fwd = none
Result = Spirent testcenter show output stream is less than 200Mbps.
I am confused about the case 3. What is the reason VM2 effects VM1 so
significantly?
How can i solve such problem? I will appreciate for your answer.
Thx
============================
??? Kai-Mao Cheng
??????? ??????? 231??
??:03-4244093 ??:0912314847
E-mail:kmcheng at cht.com.tw
============================
Please be advised that this email message (including any attachments) contains
confidential information and may be legally privileged. If you are not the
intended recipient, please destroy this message and all attachments from your
system and do not further collect, process, or use them. Chunghwa Telecom and
all its subsidiaries and associated companies shall not be liable for the
improper or incomplete transmission of the information contained in this email
nor for any delay in its receipt or damage to your system. If you are the
intended recipient, please protect the confidential and/or personal information
contained in this email with due care. Any unauthorized use, disclosure or
distribution of this message in whole or in part is strictly prohibited. Also,
please self-inspect attachments and hyperlinks contained in this email to
ensure the information security and to protect personal information.