Hi,
When I create bond4 with ConnectX-4 , mlx_flow_create return error;
When bond_port is opened, slave_port will be closed to sync bond_port
config
??bond_ethdev_start -> slave_configure->rte_eth_dev_stop??
?6?7slave_configure(struct rte_eth_dev *bonded_eth_dev,
struct rte_eth_dev *slave_eth_dev)
{
uint16_t nb_rx_queues;
uint16_t nb_tx_queues;
int errval;
struct bond_dev_private *internals = bonded_eth_dev->data->dev_private;
/* Stop slave */
errval = rte_eth_dev_stop(slave_eth_dev->data->port_id);
if (errval != 0)
RTE_BOND_LOG(ERR, "rte_eth_dev_stop: port %u, err (%d)",
slave_eth_dev->data->port_id, errval);
However, If the device is not started yetm it is not allowed to created a
flow from application.
??slave_configure -> bond_ethdev_8023ad_flow_set -> rte_flow_create ->
mlx5_flow_create??
I want to add rte_eth_dev_start before bond_ethdev_8023ad_flow_set. This
can solve my problem.