Thank you for the help!

I ran the commands and traffic is being generated correctly.

Best regards,

Rubens

On 4/19/24 14:31, Dariusz Sosnowski wrote:
Thank you for the info.

You might have run into an issue, where NIC generates backpressure to the SW 
because of very frequent switching between different VLAN priorities on Tx 
datapath in the NIC.

Could you please apply the following QoS configuration on all interfaces and 
rerun the test with different VLAN priorities?

sudo mlnx_qos -i <iface> --trust=dscp
for dscp in {0..63}; do sudo mlnx_qos -i <iface> --dscp2prio set,$dscp,0; sleep 
0.001;done

These commands will map internally all priorities to priority 0. This 
workaround should reduce the backpressure without affecting the generated 
traffic.

Best regards,
Dariusz Sosnowski

-----Original Message-----
From: Rubens Figueiredo <[email protected]>
Sent: Thursday, April 18, 2024 15:21
To: Dariusz Sosnowski <[email protected]>
Cc: [email protected]
Subject: Re: Trex with mlx5 driver - Multiple streams with different VLAN
priority causes high CPU utilization

External email: Use caution opening links or attachments


Hi Dariusz,

Thank you for the help.

If the two parallel stream use the same VLAN priority then the issue is not
visible anymore. Trex output visible below.

Different priority
CPU util.  |            96.97% |              0.0% | Tx bps L2  |         3.59 
Gbps |          0.29
bps | 3.59 Gbps Tx bps L1  |         3.64 Gbps |          0.37 bps | 3.64 Gbps
Tx pps     |       298.49 Kpps |             0 pps | 298.49 Kpps
Line Util. |            3.64 % |               0 % |

Same priority
CPU util.  |             0.54% |              0.0% | Tx bps L2  |        23.98 
Gbps |             0
bps | 23.98 Gbps Tx bps L1  |         24.3 Gbps |             0 bps | 24.3 Gbps
Tx pps     |         1.99 Mpps |             0 pps | 1.99 Mpps
Line Util. |            24.3 % |               0 % |

I have attached the requested output to the email.

Best,
Rubens

On 4/18/24 14:48, Dariusz Sosnowski wrote:
Hi Rubens,

Would you be able to provide the output of "ethtool -S <iface>" for both VFs
before and after the test?
Does the same issue appear on this system if both parallel streams use the
same VLAN priority?
Best regards,
Dariusz Sosnowski

From: Rubens Figueiredo <[email protected]>
Sent: Wednesday, April 17, 2024 19:07
To: [email protected]
Subject: Trex with mlx5 driver - Multiple streams with different VLAN
priority causes high CPU utilization

Hello community,
I am facing a strange issue in the Trex stateless code, version v3.02 and
v3.04. I am using the Mellanox Cx-5, and have created two VFs on top of the
PF 0. The mlx5_core version I am using is the 5.7-1.0.2, and the ofed version is
MLNX_OFED_LINUX-5.7-1.0.2.0 (OFED-5.7-1.0.2).
I have created the following issue in the trex-core repository
[here](https://github.com/cisco-system-traffic-generator/trex-
core/issues/1124), and was recommended to post the issue in here. In the
github issue you see screenshots of the issue I am facing.
I am trying to create two parallel streams with different VLAN priorities, but
the load generated is not what I expect it to be, and CPU util. seems incredibly
high (~99%).
I have reproduced this issue with the --software and non software version.
The script I used is below.
import stl_path
from trex.stl.api import *

import time
import pprint
from ipaddress import ip_address, ip_network

import argparse
import configparser
import os
import json


def get_packet(tos, mac_dst, ip_src, size):
      # pkt = Ether(src="02:00:00:00:00:01",dst="00:00:00:01:00:01") /
IP(src="10.0.0.2", tos=tos) / UDP(sport=4444, dport=4444)

      pkt = (
          Ether(src="00:01:00:00:00:02", dst=mac_dst)
          # Ether(dst="11:11:11:11:11:11")
          # / Dot1AD(vlan=0)
          / Dot1Q(vlan=0, prio=tos)
          / IP(src=ip_src)
          / UDP(sport=4444, dport=4444)
      )
      pad = max(0, size - len(pkt)) * "x"

      return pkt / pad

def main():
      """ """
      tx_port = 0
      rx_port = 1

      c = STLClient()

      # connect to server
      c.connect()

      # prepare our ports
      c.reset(ports=[tx_port, rx_port])

      streams = []
      s = STLStream(
          packet=STLPktBuilder(
              pkt=get_packet(4,"00:11:22:33:44:55", "10.1.0.2",512),
              # vm = vm,
          ),
          isg=0 * 1000000,
          mode=STLTXCont(pps=1.2*10**6),
          # flow_stats = STLFlowLatencyStats(pg_id = 0)
          flow_stats = STLFlowStats(pg_id=0),
      )

      streams.append(s)

      s2 = STLStream(
          packet=STLPktBuilder(
              pkt=get_packet(2,"00:11:22:33:44:55", "10.1.0.2",512),
              # vm = vm,
          ),
          isg=0 * 1000000,
          mode=STLTXCont(pps=1.2*10**6),
          # flow_stats = STLFlowLatencyStats(pg_id = 0)
          flow_stats = STLFlowStats(pg_id=1),
      )

      streams.append(s2)

      c.add_streams(streams, ports=[tx_port])

      c.clear_stats()

      c.start(ports=[tx_port], duration=60, mult="25gbpsl1")

      c.wait_on_traffic(ports=[tx_port, rx_port])

      stats = c.get_stats()
      print(stats)

if __name__ == "__main__":
      main()


And the configuration is
- port_limit: 2
    version: 2
    port_bandwidth_gb: 100
    interfaces: ["3b:00.2", "3b:00.3"]
    port_info:
      - dest_mac: 00:00:00:00:00:01
        src_mac: 00:01:00:00:00:01
      - dest_mac: 00:00:00:00:00:02
        src_mac: 00:01:00:00:00:02
    c: 14
    platform:
      master_thread_id: 8
      latency_thread_id: 27
      dual_if:
        - socket: 0
          threads:
[9,10,11,12,13,14,15,16,17,18,19,20,21,22,23,24,25,26]


BISDN GmbH
Körnerstraße 7-10
10785 Berlin
Germany

Phone: +49-30-6108-1-6100

Managing Directors:
Dr.-Ing. Hagen Woesner, Andreas Köpsel

Commercial register:
Amtsgericht Berlin-Charlottenburg HRB 141569 B VAT ID No:
DE283257294
________________________________________
--
BISDN GmbH
Körnerstraße 7-10
10785 Berlin
Germany


Phone:
+49-30-6108-1-6100


Managing Directors:
Dr.-Ing. Hagen Woesner, Andreas
Köpsel


Commercial register:
Amtsgericht Berlin-Charlottenburg HRB 141569 B VAT ID No: DE283257294

--