Thank you for the help! I ran the commands and traffic is being generated correctly.
Best regards, Rubens On 4/19/24 14:31, Dariusz Sosnowski wrote:
Thank you for the info. You might have run into an issue, where NIC generates backpressure to the SW because of very frequent switching between different VLAN priorities on Tx datapath in the NIC. Could you please apply the following QoS configuration on all interfaces and rerun the test with different VLAN priorities? sudo mlnx_qos -i <iface> --trust=dscp for dscp in {0..63}; do sudo mlnx_qos -i <iface> --dscp2prio set,$dscp,0; sleep 0.001;done These commands will map internally all priorities to priority 0. This workaround should reduce the backpressure without affecting the generated traffic. Best regards, Dariusz Sosnowski-----Original Message----- From: Rubens Figueiredo <[email protected]> Sent: Thursday, April 18, 2024 15:21 To: Dariusz Sosnowski <[email protected]> Cc: [email protected] Subject: Re: Trex with mlx5 driver - Multiple streams with different VLAN priority causes high CPU utilization External email: Use caution opening links or attachments Hi Dariusz, Thank you for the help. If the two parallel stream use the same VLAN priority then the issue is not visible anymore. Trex output visible below. Different priority CPU util. | 96.97% | 0.0% | Tx bps L2 | 3.59 Gbps | 0.29 bps | 3.59 Gbps Tx bps L1 | 3.64 Gbps | 0.37 bps | 3.64 Gbps Tx pps | 298.49 Kpps | 0 pps | 298.49 Kpps Line Util. | 3.64 % | 0 % | Same priority CPU util. | 0.54% | 0.0% | Tx bps L2 | 23.98 Gbps | 0 bps | 23.98 Gbps Tx bps L1 | 24.3 Gbps | 0 bps | 24.3 Gbps Tx pps | 1.99 Mpps | 0 pps | 1.99 Mpps Line Util. | 24.3 % | 0 % | I have attached the requested output to the email. Best, Rubens On 4/18/24 14:48, Dariusz Sosnowski wrote:Hi Rubens, Would you be able to provide the output of "ethtool -S <iface>" for both VFsbefore and after the test?Does the same issue appear on this system if both parallel streams use thesame VLAN priority?Best regards, Dariusz SosnowskiFrom: Rubens Figueiredo <[email protected]> Sent: Wednesday, April 17, 2024 19:07 To: [email protected] Subject: Trex with mlx5 driver - Multiple streams with different VLAN priority causes high CPU utilization Hello community, I am facing a strange issue in the Trex stateless code, version v3.02 andv3.04. I am using the Mellanox Cx-5, and have created two VFs on top of the PF 0. The mlx5_core version I am using is the 5.7-1.0.2, and the ofed version is MLNX_OFED_LINUX-5.7-1.0.2.0 (OFED-5.7-1.0.2).I have created the following issue in the trex-core repository[here](https://github.com/cisco-system-traffic-generator/trex- core/issues/1124), and was recommended to post the issue in here. In the github issue you see screenshots of the issue I am facing.I am trying to create two parallel streams with different VLAN priorities, butthe load generated is not what I expect it to be, and CPU util. seems incredibly high (~99%).I have reproduced this issue with the --software and non software version. The script I used is below. import stl_path from trex.stl.api import * import time import pprint from ipaddress import ip_address, ip_network import argparse import configparser import os import json def get_packet(tos, mac_dst, ip_src, size): # pkt = Ether(src="02:00:00:00:00:01",dst="00:00:00:01:00:01") / IP(src="10.0.0.2", tos=tos) / UDP(sport=4444, dport=4444) pkt = ( Ether(src="00:01:00:00:00:02", dst=mac_dst) # Ether(dst="11:11:11:11:11:11") # / Dot1AD(vlan=0) / Dot1Q(vlan=0, prio=tos) / IP(src=ip_src) / UDP(sport=4444, dport=4444) ) pad = max(0, size - len(pkt)) * "x" return pkt / pad def main(): """ """ tx_port = 0 rx_port = 1 c = STLClient() # connect to server c.connect() # prepare our ports c.reset(ports=[tx_port, rx_port]) streams = [] s = STLStream( packet=STLPktBuilder( pkt=get_packet(4,"00:11:22:33:44:55", "10.1.0.2",512), # vm = vm, ), isg=0 * 1000000, mode=STLTXCont(pps=1.2*10**6), # flow_stats = STLFlowLatencyStats(pg_id = 0) flow_stats = STLFlowStats(pg_id=0), ) streams.append(s) s2 = STLStream( packet=STLPktBuilder( pkt=get_packet(2,"00:11:22:33:44:55", "10.1.0.2",512), # vm = vm, ), isg=0 * 1000000, mode=STLTXCont(pps=1.2*10**6), # flow_stats = STLFlowLatencyStats(pg_id = 0) flow_stats = STLFlowStats(pg_id=1), ) streams.append(s2) c.add_streams(streams, ports=[tx_port]) c.clear_stats() c.start(ports=[tx_port], duration=60, mult="25gbpsl1") c.wait_on_traffic(ports=[tx_port, rx_port]) stats = c.get_stats() print(stats) if __name__ == "__main__": main() And the configuration is - port_limit: 2 version: 2 port_bandwidth_gb: 100 interfaces: ["3b:00.2", "3b:00.3"] port_info: - dest_mac: 00:00:00:00:00:01 src_mac: 00:01:00:00:00:01 - dest_mac: 00:00:00:00:00:02 src_mac: 00:01:00:00:00:02 c: 14 platform: master_thread_id: 8 latency_thread_id: 27 dual_if: - socket: 0 threads: [9,10,11,12,13,14,15,16,17,18,19,20,21,22,23,24,25,26] BISDN GmbH Körnerstraße 7-10 10785 Berlin Germany Phone: +49-30-6108-1-6100 Managing Directors: Dr.-Ing. Hagen Woesner, Andreas Köpsel Commercial register: Amtsgericht Berlin-Charlottenburg HRB 141569 B VAT ID No:DE283257294________________________________________-- BISDN GmbH Körnerstraße 7-10 10785 Berlin Germany Phone: +49-30-6108-1-6100 Managing Directors: Dr.-Ing. Hagen Woesner, Andreas Köpsel Commercial register: Amtsgericht Berlin-Charlottenburg HRB 141569 B VAT ID No: DE283257294
-- BISDN GmbH Körnerstraße 7-10 10785 Berlin GermanyPhone: +49-30-6108-1-6100
Managing Directors:Dr.-Ing. Hagen Woesner, Andreas Köpsel
Commercial register:Amtsgericht Berlin-Charlottenburg HRB 141569 B
VAT ID No: DE283257294