Hello,

I have an error when simulating unequal mass binaries with  PRThorns GRHydro 
for certain combinations of EOS and mass ratios.

Using the same parameter file for an equal mass binary case, seems to work with 
various EOSs, and for certain EOSs, even for unequal mass.

Any inkling of why this might happen? I tried with both ppm and weno 
recon_method, and with higher refinement.
What do you think would help?


Maria
____________

WARNING level 1 from host compute-14.marshall.local process 16
  while executing schedule bin CCTK_POSTSTEP, routine 
GRHydro::check_GRHydro_C2P_failed
  in thorn GRHydro, file GRHydro_Con2Prim.F90:1781:
  -> ; stopping the code.

_______________________
Maria C. Babiuc Hamilton, Ph.D.
Professor, Department of Physics
College of Science, Marshall University,
1 John Marshall Drive, Huntington, WV, 25755
Room S 257, Phone: (304)696-2754

_______________________________________________
Users mailing list
[email protected]
http://lists.einsteintoolkit.org/mailman/listinfo/users

Reply via email to