On 02/14/2011 06:10 PM, Reuti wrote:
> Hi,
> 
> Am 14.02.2011 um 17:15 schrieb Richard Ems:
> 
>> If I understand things correctly, if max_unheard time is reached for a
>> host, the queue instances on that host will be set to status unknown.
> 
> Yep.
> 
> 
>> Then, if reschedule_unknown is not 0, jobs will be rescheduled after
>> waiting the reschedule_unknown time.
> 
> Yep (and submitted with "-r y" or defined by queue's setting).
> 
> 
>> Will the host be rechecked during this time? What if the host that set
>> to "status unknown" becomes reachable again before rescheduling? Will
>> the status change back and no reschedule will happen?
> 
> Yep.
> 
> 
>> OR why should a system wait before rescheduling if the system status
>> becomes unknown? Which would be a sensible value for reschedule_unknown?
> 
> It's the time you get granted after you noticed in `qhost` that a machine is 
> gone to check and fix the issue.
> 
> -- Reuti

Ok, perfect as usual Reuti, many thanks!

Richard


-- 
Richard Ems       mail: [email protected]

Cape Horn Engineering S.L.
C/ Dr. J.J. Dómine 1, 5º piso
46011 Valencia
Tel : +34 96 3242923 / Fax 924
http://www.cape-horn-eng.com
_______________________________________________
users mailing list
[email protected]
https://gridengine.org/mailman/listinfo/users

Reply via email to