Hi Stephen, Thanks for your reply.
> (fix for this is in all the source distributions, or upgrade to > Univa Grid Engine v8 later this month) I'm looking forward to the new release. We're currently running 6.2u2, I believe, and an update is on my task list. Sounds like the timing might be perfect :-) > 1. Keep it very simple with a high queue and a low queue. That, unfortunately, doesn't seem to do what I'm looking for. There isn't a clear subordination here; I want both queues to be able to fill both groups of machines if that makes sense at the time. But I want one group of machines to see one queue as subordinate, and the other group of machines to see the other queue as subordinate. So each working group has their own machines, but they "borrow" the other groups' boxen if they're unused. > 2. Remove the pe_list from both those queues. I don't currently have any PEs set up. I was hoping to - but it's not the end of the world if I can't. Am I asking for the moon on a stick? Thanks! Vic. _______________________________________________ users mailing list [email protected] https://gridengine.org/mailman/listinfo/users