Am 06.10.2011 um 16:28 schrieb Robert Horton:

On Thu, 2011-10-06 at 12:20 +0100, Stephen Willey wrote:
I have an RQS that I only want to be enabled between 8am and 8pm.
Has anyone done this before? There doesn't seem to be anything in the
specification for this purpose so I'm guessing I'm going to have to
cron something like qconf -Mrqs

You could have an off-peak queue and use a calendar to either suspend or
disable this during peak hours then just put the resource quota on the
other queue.

Yes, this is an option. But a suspension (i.e. stopping the jobs) shouldn't be used, as you might end up with all jobs suspended and the normal queue with set RQS being empty.

Changing in the RQS by a cron job is working and I used it at some time. Having a time specification inside the RQS itself would be nice of course.

-- Reuti


Rob