Reuti <[email protected]> writes:

> It is set during boot when the daemon is started (the limit can be different 
> from a later user login). But you can check the parameters:
>
> S_DESCRIPTORS, H_DESCRIPTORS
>
> in `man sge_conf`.

To avoid possible confusion:  those are execd parameters.  MAX_DYN_EC is
the relevant qmaster one, limited by the process file descriptor limit
and a number set aside for static connexions.  (It was raised a while
ago from a much lower value which only allowed a few clients.)

-- 