Am 05.02.2013 um 11:02 schrieb Markus Koeberl: > On Tuesday 05 February 2013 10:54:57 Reuti wrote: >> Hi, >> >> Am 05.02.2013 um 10:08 schrieb Markus Koeberl: >>> I am trying to use a load_sensor with gridengine on debian squeeze >>> (6.2u5-1squeeze1). >>> My script get used but values only get asked one time after start and >>> after a change in the script. But not regulary after load_report_time. >>> qconf -se <host> does not display the reported values. >> >> somehow this sounds that the script is not running all the time. Do you see >> on the node and output like: >> >> reuti@node02:~> ps -e f >> PID TTY STAT TIME COMMAND >> ... >> 5129 ? Sl 371:12 /usr/sge/bin/lx24-amd64/sge_execd >> 5200 ? S 7:56 \_ /bin/sh /usr/sge/cluster/tmpspace.sh > > yes: > > 30031 ? Sl 0:09 /usr/lib/gridengine/sge_execd > 30037 ? S 0:00 \_ /bin/sh -c > /usr/local/SPSCscripts/gridengine/gridengine_loadsensor_cfs > 30040 ? S 0:00 | \_ /usr/bin/perl > /usr/local/SPSCscripts/gridengine/gridengine_loadsensor_cfs
Aha, Perl. This is then an issue of the buffered output I guess. -- Reuti > > regards > Markus Koeberl > -- > Markus Koeberl > Graz University of Technology > Signal Processing and Speech Communication Laboratory > E-mail: [email protected] _______________________________________________ users mailing list [email protected] https://gridengine.org/mailman/listinfo/users