Thank you for your answer
To be clear, I want to kill a job without h_rt option at submission step.
To do this, should I have to setup h_rt and s_rt filed in queue configuration?
is that all?

Sangmin

2013. 3. 27., 오후 6:16, William Hay <[email protected]> 작성:

> On 27 March 2013 01:51, Sangmin Park <[email protected]> wrote:
>> Hello,
>> 
>> I have a question about configuring a queue.
>> I want to kill job if a batch file of job does not include wall clock time,
>> h_rt option with termination message.
>> Does anyone know how to do it?
>> 
> It's not clear when you want the job killed if it doesn't set a time
> limit.  At submission or after some predefined runtime?
> 
> Do you want to impose an overall limit as well?  If so then filling in
> the h_rt or s_rt field of the queue configuration should work.
> Or you could fill in a default request for h_rt/s_rt in the central
> sge_request file.
> Finally you could just use a jsv to check that a value has been set
> for h_rt or s_rt and either set one or reject the job at submission.
>> Thanks in advance.
>> 
>> 
>> Sangmin