Hello, We have three HPC systems called A, B, and C and these could be accessible through the login node. SGE is installed login node. A and B HPC systems are consist of master node and computing nodes respectively and connected gigabit ethernet between them. But, C HPC system has ideal configuration, not ethernet. It's wired infiniband network.
Each HPC system has two kinds of network, one for management using gigabit network, another for computing using gagiabit for A, B system and infiniband for C system. SGE uses management network. Problems arise in C HPC system. SGE uses management network. So, when a user submits a job using sge, it could be use gigabit network, not infiniband network. To use infiniband network, sge has to work with infiniband network in all cases. Does SGE work in heterogeneous network systems well? -Sangmin
_______________________________________________ users mailing list [email protected] https://gridengine.org/mailman/listinfo/users