Thank you. I found better docs for my M20 now (it came without any!!!) and the 8bit sending works now, atleast with "normal" SMS. Unfortunately this doesn't help me with my WAP Push SMS problem. The PDU generated by kannel is either wrong or M20 incompatible:
00 51 :UDHI (User Data Header Indicator) - optional 00 :MR (Message Reference) 0C :Dest Address Len 91 :Dest Address Type xx :Dest Address goes here... xx xx xx xx xx 00 :Protocol ID 04 :DCS (Data Coding Scheme) A7 :SCTS (Service Center Time Stamp) 70 :UDL 06 :UDH (User Data Header) - optional 05 :Port Address IEI 04 :LEN 0B :Dest Port 84 :Dest Port 23 :Org Port F0 :Org Port 04 :TID (Push ID) 06 :PDU Type (PUSH) 17 :HeaderLen AE :Content Type 96 :SI Doc goes here... 6C6F63616C686F73743A3930383000AF 808DCFB48002056A0045C60C03776170 2E696F626F782E666900110331407769 72616C2E636F6D00080AC30720000625 15231510C30420030630010357616E74 20746F20746573742061206665746368 3F000101 I tried modifying nearly every parameter, but my M20 always tells me that the UDL doesn't match the user data. (CMS error 304) This Push SMS leaves the M20, but isn't delivered to my mobile: 0041040D919471920157780004F7440 605040B8423F0010601AE02056A0045 C60C037761702E7961686F6F2E636F6 D0011033132333400070AC307200207 0115000010C30420020730010361626 36465000101 I think its because the Dest. Adr. Length is 0D while in the PDU above it is 0C (which is the right value), but with 0C I found absolutely no way to get the PDU through the M20... always the UDL error! It's really annoying and probably theres only one byte wrong... Any ideas whats wrong with the PDU generated by Kannel? Any ideas how I can change the 0D to 0C in the second example, so that the whole PDU is still correct? greetings, Ralph > "Enzo dell'Aquila" <[EMAIL PROTECTED]> > Sent by: [EMAIL PROTECTED] > 09.08.2002 15:29 > > To: <[EMAIL PROTECTED]>, <[EMAIL PROTECTED]> > cc: > Subject: Re: Siemens M20 - Error 322 (Memory full) > >Two ways: > >a) put the sim in a phone and use phone to delete sms ;) >b) AT+CMGD for deleting SMS from preferred message storage location. Use >AT+CMGD=? : shows whether command has been implemented. > >Bye, >Enzo >Hi all, > >I tracked down my WAP Push sending problem to my M20 >being unable to send 8bit messages with the command: > >AT+CMGW=19 >> 0011000C... (example from Siemens docs or PDU Spy generated 8bit SMS) >+CMS ERROR: 322 > >Any ideas how I can free the memory? > >greetings, >Ralph