Thank you.
 I found better docs for my M20 now (it came without any!!!)
 and the 8bit sending works now, atleast with "normal" SMS.
 Unfortunately this doesn't help me with my WAP Push SMS problem.
 The PDU generated by kannel is either wrong or M20 incompatible:

00
51   :UDHI (User Data Header Indicator) - optional
00   :MR (Message Reference)
0C   :Dest Address Len
91   :Dest Address Type
xx   :Dest Address goes here...
xx
xx
xx
xx
xx
00    :Protocol ID
04    :DCS (Data Coding Scheme)
A7    :SCTS (Service Center Time Stamp)
70    :UDL
06    :UDH (User Data Header) - optional
05    :Port Address IEI
04    :LEN
0B    :Dest Port
84    :Dest Port
23    :Org Port
F0    :Org Port
04    :TID (Push ID)
06    :PDU Type (PUSH)
17    :HeaderLen
AE    :Content Type
96    :SI Doc goes here...
6C6F63616C686F73743A3930383000AF
808DCFB48002056A0045C60C03776170
2E696F626F782E666900110331407769
72616C2E636F6D00080AC30720000625
15231510C30420030630010357616E74
20746F20746573742061206665746368
3F000101

I tried modifying nearly every parameter, but my M20 always
tells me that the UDL doesn't match the user data. (CMS error 304)

This Push SMS leaves the M20, but isn't delivered to my mobile:
0041040D919471920157780004F7440
605040B8423F0010601AE02056A0045
C60C037761702E7961686F6F2E636F6
D0011033132333400070AC307200207
0115000010C30420020730010361626
36465000101

I think its because the Dest. Adr. Length is 0D while in the
PDU above it is 0C (which is the right value), but with 0C I found
absolutely no way to get the PDU through the M20... always the UDL error!
It's really annoying and probably theres only one byte wrong...

Any ideas whats wrong with the PDU generated by Kannel?
Any ideas how I can change the 0D to 0C in the second example,
so that the whole PDU is still correct?

greetings,
Ralph



 >   "Enzo dell'Aquila" <[EMAIL PROTECTED]>
 >   Sent by: [EMAIL PROTECTED]
 >   09.08.2002 15:29
 >
 >         To: <[EMAIL PROTECTED]>, <[EMAIL PROTECTED]>
 >         cc:
 >         Subject: Re: Siemens M20 - Error 322 (Memory full)
 >
 >Two ways:
 >
 >a) put the sim in a phone and use phone to delete sms ;)
 >b) AT+CMGD for deleting SMS from preferred message storage location. Use
 >AT+CMGD=? : shows whether command has been implemented.
 >
 >Bye,
 >Enzo
 >Hi all,
 >
 >I tracked down my WAP Push sending problem to my M20
 >being unable to send 8bit messages with the command:
 >
 >AT+CMGW=19
 >> 0011000C... (example from Siemens docs or PDU Spy generated 8bit SMS)
 >+CMS ERROR: 322
 >
 >Any ideas how I can free the memory?
 >
 >greetings,
 >Ralph



Reply via email to