Title: %p parameter problem with UCP connection

Hi all,

I am using Kannel to make a SMS gateway for R&D needs.
Kannel is connected to a SMSC running live via the UCP protocol.

I encouter a problem that makes me think that there is a bug in Kannel.

Explanation :
The SMSC has an internal routing engine that redirect all the SM sent to a range of number (01.23.45.67.xx for instance, french number ;)) to the kannel gateway.

The problem is that the kannel %p parameter does not match with the real receiver (01.23.45.67.89), in fact the %p parameter is the short ID corresponding to the kannel short ID 22 222 for example.

So i cannot know the sender real number and i need it.
I 've checked the UCP flow and UCP packets are correct and well built with the real receiver number (01.23.45.67.89).

I use Kannel 1.2.1.

Someone knows this problem ?

Thanks for your help.

Jean-No�l HEYRAUD
France T�l�com
Research & D�veloppement