Did someone remember about FAQ about keepalive and sim buffering FAQ ? Regards
-----Original Message----- From: Aarno Syvanen [mailto:[EMAIL PROTECTED] Sent: lundi 2 mai 2005 09:51 To: info.ubichip IMAP Cc: [email protected] Subject: Re: DLR success issue Are numbers you are using allocated ? Non-allocated numbers would explain your failure ratio. Aarno On 29.4.2005, at 14:47, info.ubichip IMAP wrote: > Hello, > > I'm running Kannel 1.4.2 (and mySQL) with a pool of Nokia 12 modems. > I'm > using this gateway for sending sms. > I got some troubles when I have some mass sending, the success (SMS > that > arrive successful on the handset) ratio is not constant and some time > is > under 30% (usually it come to 75/85%). > > > example : > Total MT = 1297 > Total MO = 1990 > Dont > _________________________________ > Total MO NACK = 58 > Total MO Non Delivered = 27 > Total MO ACK = 1240 > Total MO Buffered = 146 > Total MO Success = 519 > > I make a correction in the kannel code in order to remove the bug with > multiple senders and the limitation of 255 ts : the DLR are updated > based on > ts AND destination AND smsc. I could provide this code for people who > want > it. > > My concern is the actual ratio is not so good and I don't know why. > > here is my modem.cong and the extract of the setup of kannel.conf for > the > smsc AT. > > Does someone have idea about the keepalive paramaters (I setup it to 6 > sec)? > What about sim buffering ? > > Thanks for your help. > > > group = smsc > smsc = at > smsc-id = Titi2 > allowed-smsc-id = toto;titi2 > #modemtype = wavecom | premicell | siemens | siemens-tc35 | falcom | > nokiaphone | ericsson > modemtype = nokia12 > device = /dev/ttyS7 > pin = 0000 > # validity period is 167 (24 hours+ x jours) > validityperiod = 169 > # ping du modem toutes les 60s > keepalive = 6 > # numero de tel de ce GSM > my-number = 00336xxxxxxxx > #throughput = 2 > sim-buffering = true > # pour ISO 8859-1 > #alt-charset = "ASCII" > > > > > # Modems configuration > # > # Example and default values > # > # group = modems > # id = "my-id" > # name = "my-name" > # detect-string = "MODEM" > # detect-string2 = "" [Default] > # init-string = "AT+CNMI=1,2,0,0,0" [Default] > # speed = 9600 [Default] > # enable-hwhs = "AT+IFC=2,2" [Default] > # need-sleep = false [Default] > # no-pin = false [Default] > # no-smsc = false [Default] > # sendline-sleep = 100 [Default, miliseconds] > # keepalive-cmd = "AT" [Default] > # broken = false [Default] > # message-storage = "SM" > # enable-mms = false [Default] > > > # If modemtype=auto, try everyone and defaults to this one > group = modems > id = generic > name = "Generic Modem" > > group = modems > id = wavecom > name = Wavecom > detect-string = "WAVECOM" > > group = modems > id = premicell > name = Premicell > detect-string = "PREMICEL" > no-pin = true > no-smsc = true > > group = modems > id = siemens_tc35 > name = "Siemens TC35" > detect-string = "SIEMENS" > detect-string2 = "TC35" > init-string = "AT+CNMI=1,2,0,1,1" > speed = 19200 > enable-hwhs = "AT\\Q3" > need-sleep = true > > group = modems > id = siemens_m20 > name = "Siemens M20" > detect-string = "SIEMENS" > detect-string2 = "M20" > speed = 19200 > enable-hwhs = "AT\\Q3" > keepalive-cmd = "AT+CBC;+CSQ" > need-sleep = true > > group = modems > id = siemens_sl45 > name = "Siemens SL45" > detect-string = "SIEMENS" > #detect-string2 = "SL45" > #init-string = "AT+CNMI=1,2,2,2,1;+CMGF=0" > init-string = "AT+CNMI=1,2,2,2,1;+CMGF=0" > keepalive-cmd = "AT+CBC;+CSQ" > speed = 19200 > enable-hwhs = "AT\\Q3" > need-sleep = true > #message-storage = "ME" > message-storage = "SM" > > group = modems > id = nokiaphone > name = "Nokia Phone" > detect-string = "Nokia Mobile Phone" > need-sleep = true > keepalive-cmd = "AT+CBC;+CSQ" > enable-mms = true > > group = modems > id = nokia12 > name = "Nokia 12" > detect-string = "Nokia" > need-sleep = true > #keepalive-cmd = "AT+CBC;+CSQ" > keepalive-cmd = "AT+CSQ" > enable-mms = true > # init-string = "AT+CNMI=2,2,0,1,1" > init-string = "ATE0+CNMI=2,0,0,1,0" > message-storage = "SM" > no-pin =true > > > group = modems > id = sagem > name = "Sagem" > detect-string = "Sagem" > need-sleep = true > #keepalive-cmd = "AT+CBC;+CSQ" > #enable-mms = true > init-string = "AT+CNMI=2,0,0,1,0" > enable-hwhs = "AT&k3" > speed = 9600 > message-storage = "SM" > > > group = modems > id = wave2 > name = "wave2" > detect-string = "WAVECOM" > need-sleep = true > keepalive-cmd = "AT+CBC;+CSQ" > #enable-hwhs = "AT+IFC=2,2" > #enable-mms = true > init-string = "ATE0+CNMI=2,1,0,1,1" > speed = 9600 > message-storage = "SM" > > > > group = modems > id = falcom > name = "Falcom" > detect-string = "Falcom" > no-smsc = true > > group = modems > id = ericsson_r520m > name = "Ericsson R520m" > detect-string = "R520m" > init-string = "AT+CNMI=3,2,0,0" > > group = modems > id = ericsson_t68 > name = "Ericsson T68" > detect-string = "T68" > init-string = "AT+CNMI=3,3" > keepalive-cmd = "AT+CBC;+CSQ" > broken = true > > group = modems > id = alcatel > name = "Alcatel" > detect-string = "Alcatel" > init-string = "AT+CNMI=3,2,0,0" > >