Hi Mario,
be sure all your Kannel processes are dead before trying to start them over again.
Rodrigo.
----- Original Message ----- From: "Mario Noboa" <[EMAIL PROTECTED]>
To: <[email protected]>
Sent: Thursday, May 19, 2005 12:14 PM
Subject: ESME Already in Bound State
Hi list!
I'm configuring two smpp connection, one for sending stuff, and one for receiving stuff.. With Rx i have a problem.....
I got the follow message:
2005-05-19 09:04:35 [7825] [7] WARNING: SMPP: PDU NULL terminated string has
no NULL.
2005-05-19 09:04:35 [7825] [7] ERROR: SMPP[2]: SMSC rejected login to
receive, code 0x00000005 (ESME Already in Bound State).
2005-05-19 09:04:35 [7825] [7] ERROR: SMPP[2]: I/O error or other error.
Re-connecting.
2005-05-19 09:04:35 [7825] [7] ERROR: SMPP[2]: Couldn't connect to SMS
center (retrying in 10 seconds).
Any help i'd greatly appreciate it !
Mario
Here is my conf file:
group = smsc smsc = smpp smsc-id = Tx host= XXX.XXX.XXX.XX port = 17603 receive-port = 0 smsc-username = user smsc-password = user2 source-addr-ton = 2 source-addr-npi = 1 dest-addr-ton = 2 dest-addr-npi = 1 system-type = smpp interface-version = 34
group = smsc smsc = smpp smsc-id = Rx host= XXX.XXX.XXX.XX port = 0 receive-port = 3000 smsc-username = user_r smsc-password = user201 source-addr-ton = 2 source-addr-npi = 1 dest-addr-ton = 2 dest-addr-npi = 1 interface-version = 34 system-type = smpp