Gottfried,

Looks like you have your login details wrong, check with your operator / sms provider what details you should be using. You need 3 things, the username (system id), password and system type. Only if you have all 3 of these correct will you be able to bind (although some providers do not check the system type).

Regards

Ben
On 8 Jan 2007, at 15:43, Huber, Gottfried wrote:



Hello to all

I try to configure kannel with transceiver-mode only.


transceiver-mode bool
Attempt to use a TRANSCEIVER mode connection to the SM-SC. It uses the standard transmit 'port', there is no need to set 'receive- port'. This is a SMPP 3.4 only feature and will not work on an earlier SM-SC. This will try a bind_transceiver only and will not attempt to fall back to doing transmit and receive on the same connection.

But i have still the error:

[8364] [6] ERROR: SMPP[ONE2]: SMSC rejected login to transmit, code 0x0000000f (Invalid System ID).

Thanks für helping me

Gottfried



Reply via email to