Hi Sagman I think the CNMI parameters are wrong
Look here http://developer.sonyericsson.com/ for the AT commando manual for your phone and review the values for CNMI command. I got a similar problem with my T68i some time ago and I fixed it changing that init string Regards Alvaro -----Mensaje original----- De: sagmam [mailto:[EMAIL PROTECTED] Enviado el: Jueves, 15 de Febrero de 2007 02:45 Para: [email protected] Asunto: Can't send sms over 56 chars Hi all, I'm trying to send an SMS with non-Latin chars using Sony Ericsson K610i, and I can't seem to send over 56 chars. This is the command I use: http://localhost:15000/cgi-bin/sendsms? username=tester&password=foobar&from=xxxx&to=yyyy&coding=2&text=%00%30%00%31 ... My only option is to use coding=2 when I send non-Latin, correct? Just for testing, I'm sending the string 0123.90123.9. Debug output in bearerbox when sending 56 chars: 2007-02-14 17:37:12 [4932] [6] DEBUG: AT2[CELL]: --> 0011000C917952425684060008A770003000310032003300340035003600370038003900300 0310032003300340035003600370038003900300031003200330034003500360037003800390 030 0031003200330034003500360037003800390030003100320 033003400350036003700380039003000310032003300340035 2007-02-14 17:37:12 [4932] [6] DEBUG: AT2[CELL]: --> ^Z 2007-02-14 17:37:14 [4932] [6] DEBUG: AT2[CELL]: <-- > 2007-02-14 17:37:14 [4932] [6] DEBUG: AT2[CELL]: <-- +CMGS: 60 2007-02-14 17:37:14 [4932] [6] DEBUG: AT2[CELL]: <-- OK 2007-02-14 17:37:14 [4932] [6] DEBUG: AT2[CELL]: send command status: 0 Debug output in bearerbox when sending 57 chars: 2007-02-14 17:37:00 [4932] [6] DEBUG: AT2[CELL]: --> 0011000C917952425684060008A772003000310032003300340035003600370038003900300 0310032003300340035003600370038003900300031003200330034003500360037003800390 030 0031003200330034003500360037003800390030003100320 0330034003500360037003800390030003100320033003400350036 2007-02-14 17:37:00 [4932] [6] ERROR: AT2[CELL]: Couldnot write to device. 2007-02-14 17:37:00 [4932] [6] ERROR: System error 13: Permission denied 2007-02-14 17:37:00 [4932] [6] DEBUG: AT2[CELL]: --> ^Z 2007-02-14 17:37:00 [4932] [6] DEBUG: AT2[CELL]: <-- > 2007-02-14 17:37:00 [4932] [6] DEBUG: AT2[CELL]: <-- +CMS ERROR: 304 2007-02-14 17:37:00 [4932] [6] ERROR: AT2[CELL]: CMS ERROR: +CMS ERROR: 304 (Invalid PDU mode parameter) No difference in the header except in last byte (data length): 70h = 112 = 56*2, as opposed to 72h = 114 = 57*2. Another interesting thing is that the total number of bytes with 56 chars (inc header) is 127, and with 57 chars - 129 bytes. It is as if there is some 128 byte limit somewhere. This is my 'modems' group in the .conf file: group = modems id = sephone name = "Sony Ericsson K610" detect-string = "Sony Ericsson K610" need-sleep = true init-string = "AT+CNMI=2,3,0,1,0" Any ideas how to break the 56 char limit??? Btw, in the K610i spec, the limit is 240 chars (or 120 UCS2 chars). Thanks, Sagi Mann