In order to determine if the problem is wrong smsc number
I do set sms-center and no-smsc with either true and false values,
but the PDU stills doesn't include the SMSC number.
Here is relevant part of kannel.conf:

group = smsc
smsc = at
smsc-id = mt_modem
modemtype = wavecom
device = /dev/ttyUSB0
speed = 115200
sms-center = +5294100001410
my-number = +52XXXXXXX

group = modems
id = wavecom
name = Wavecom
detect-string = "WAVECOM"
#I've tried with true but still no smsc number included in PDU
no-smsc = false


Here is an example of PDU generated, notice no SMSC number included
-----------------------------------------------------
DEBUG: AT2[mt_modem]: --> AT+CMGS=17^M
DEBUG: AT2[mt_modem]: <-- >
DEBUG: AT2[mt_modem]: send command status: 1
DEBUG: AT2[mt_modem]: --> 0011000A8155739073740000A704F4F29C0E
DEBUG: AT2[mt_modem]: --> ^Z
DEBUG: AT2[mt_modem]: <-- >
DEBUG: AT2[mt_modem]: <-- ERROR
ERROR: AT2[mt_modem]: Generic error: ERROR

new question:
Is it possible to make kannel generate PDU with smsc number?


regards,
Gerardo

PS: yes, I know kannel is using default smsc number, also I can see at beggining of log:
DEBUG: AT2[mt_modem]: --> AT+CSCA="+5294100001410"^M
DEBUG: AT2[mt_modem]: <-- OK

but, since I don't see any other place to look for error I first want to make sure
the pdu gets all info needed in itself.



Reply via email to