Hi to all, I'm a new Kannel user and I think it's fantastic! I've set up an UCP connection in minutes and it's work very well.
I have an issue I'm not able to solve: I have to set the Xser on location FE this is a sample message using Xser on FE 00/00117/O/51/3391234567/4141//1/////////2207071130//////3//4D657373616767696F2064692070726F7661//////////020100FE06373737373737///CC in this sample I assigned the value 777777 on location FE FE06373737373737 FE 06 (length of value: 6 digits) 373737373737 (my value 777777) It's the same case of billing id but use "FE" instead of "0C" Is it possible to format the udh field in order to assign this value? Otherwise, how can I modify the source in order to assign the billing ID to the FE location instead of the OC? thanks a lot for you help Francesco
