Onsdag 19 november 2008 13:19:13 skrev Dave Jong A Lock:
> Hi all,
>
> I have a transmitter only smsc. the bearerbox constantly gives me an
> error cannot connect (because it also tries to connect as receiver).
>
> Is it possible to change this in the configuration?
>
> I found an old thread about this:
>
> Binding as a transmitter only
> Ronan Derby
> Mon, 14 Jan 2002 08:31:08 -0800
>
>
>
> Does anyone have any follow up on this?
>
> Dave

If your operator only gave you a transmitter connection, then just remove the 
receive-port line from the smsc group, and set transceiver-mode = 0.

Kannel will then only bind to the port as a transmitter, and not try to 
connect as receiver.

-- 
--------------------------------
Arne K. Haaje   | www.drx.no
T: 69 51 15 52  | M: 92 88 44 66
--------------------------------

Reply via email to