just use different smsc-id on each...
is there any reason why you are using the same one on both?

On Wed, May 6, 2009 at 8:53 PM, Mario Noboa <[email protected]> wrote:
>
> Hi guys,  I have a question...
>
> I have two transmitters with diferent system-id. I defined both with the
> same smsc-id.  The operator ask me, send MT's depending of shortcodes.
>
> The question is, can I set a parameter for kannel send the MT for an
> specific system-id, with the same smsc id?
>
> thanks a lot!!
>
> Mario
>
>
> PS: my configuration...
>
> group = smsc
> smsc = smpp
> smsc-id = OPERATOR
> host = xx.xx.xx.xx
> port = 8808
> receive-port = 0
> smsc-username = user3334
> smsc-password = user1
> system-type = NULL
> source-addr-ton = 0
> source-addr-npi = 1
> dest-addr-ton = 2
> dest-addr-npi = 1
>
>
> group = smsc
> smsc = smpp
> smsc-id = OPERATOR
> host = xx.xx.xx.xx
> port = 8808
> receive-port = 0
> smsc-username = user3335
> smsc-password = user2
> system-type = NULL
> source-addr-ton = 0
> source-addr-npi = 1
> dest-addr-ton = 2
> dest-addr-npi = 1
>
>



-- 
Juan Nin
3Cinteractive / Mobilizing Great Brands
http://www.3cinteractive.com

Reply via email to