On Fri, May 22, 2009 at 8:36 AM, sangprabv <[email protected]> wrote:
> Hi,
> I got SMPP error 1034 during binding to my telco. What does it means?
> TIA.
I've checked the SMPP error codes:
1034 or 0x0000040A is
ESME_RINVQTTL 0x0000040A Invalid qos_time_to_live Valid integer
which is a part of SIMPLEWIRE SPECIFIC SMPP CODES

As Alejandro suggested send the logs ;)

BR, Jovan