Good Day, I would like to use kannel in configuration with smsc based on gsm-terminal Siemens MC35i. We have got some problems while setting the kannel, which I failed to solve. The problem is that our gsm-operator does not accept messages which have 81h in the DA field of the number type.
In particular the situation is the following: If I control the modem by minicom and send an sms with the following commands: AT&F AT+CNMI=1,2,0,1,1 AT+CMSG=24 >0011000B919713141110F10000AA0BCBB0DB5D6653CB737A08<Ctrl+Z> Than the sms is sent to my phone. If I send an sms through kannel by web-interface http://smsgate.appm.local:13013/cgi-bin/sendsms?username=&password=&to=+7MMMXXXXXXX&text=KannelTest! than the sms is converted into the following PDU: 0011000B819713141110F10000AA0BCBB0DB5D6653CB737A08 and goes to the operator, but a callback message comes and give us “ the message can not be sent because the recipient number should be stated in the international format" (as far as I understand the fifth byte should be 91h). Any notation of unified-prefix parameters and sms-center in config does not help to change the outgoing PDU… Please be so kind to advise us how to set up the kannel and make the kannel operate with 91h number type? kannel 1.4.2 is compiled from repo rpm-forge on the base of CentOS5. Kannel config: # APPM kannel configuration file group = core admin-port = 13000 admin-password = ****** smsbox-port = 13001 log-file = /var/log/kannel/bearerbox.log log-level = 0 access-log = /var/log/kannel/access.log dlr-storage = internal store-type = spool store-location = /var/spool/kannel/ group = smsbox bearerbox-host = localhost smsbox-id = APPM-smsbox log-file = /var/log/kannel/smsbox.log log-level = 0 sendsms-port = 13013 group = smsc smsc = at smsc-id = APPM-smsc #log-file = /var/log/kannel/smsc_at.log #log-level = 0 modemtype = auto device = /dev/ttyS0 connect-allow-ip = 127.0.0.1 speed = 115200 sim-buffering = true unified-prefix = "+7" sms-center = "+7MMMXXXXXXX" group = smsbox-route smsbox-id = APPM-smsbox smsc-id = APPM-smsc group = modems id = SIEMENS MC35i name = "Siemens_MC35i" detect-string = "SIEMENS" detect-string2 = "MC35i" init-string = "AT+CNMI=1,2,0,1,1" enable-hwhs = "AT\\Q3" need-sleep = true message-storage = sm group = sendsms-user username = "" password = "" default-sender = +7MMMXXXXXXX group = sms-service keyword = default text = "No service specified" catch-all = true Any help would be greatly appreciated! Best regards, Alexander Gubanov.