Good Day,

I would like to use kannel in configuration with  smsc based on
gsm-terminal Siemens MC35i. We have got some problems while setting
the kannel, which I failed to solve. The problem is that our
gsm-operator does not accept messages which have 81h in the DA field
of the number type.

In particular the situation is the following:

If I control the modem by minicom and send an sms with the following commands:

AT&F
AT+CNMI=1,2,0,1,1
AT+CMSG=24
>0011000B919713141110F10000AA0BCBB0DB5D6653CB737A08<Ctrl+Z>

Than the sms is sent to my phone.

If I send an sms through kannel by web-interface
http://smsgate.appm.local:13013/cgi-bin/sendsms?username=&password=&to=+7MMMXXXXXXX&text=KannelTest!
than the sms is converted into the following PDU:

0011000B819713141110F10000AA0BCBB0DB5D6653CB737A08

and goes to the operator, but  a callback message comes and give us “
the message can not be sent because the recipient number  should be
stated in the international format" (as far as I understand the fifth
byte should be 91h). Any notation of unified-prefix parameters and
sms-center in config does not help to change the outgoing PDU…

Please be so kind to advise us how to set up the kannel and make the
kannel operate with  91h number type?

kannel   1.4.2 is compiled  from repo rpm-forge on the base of CentOS5.

Kannel config:

# APPM kannel configuration file
group = core
admin-port = 13000
admin-password = ******
smsbox-port = 13001
log-file = /var/log/kannel/bearerbox.log
log-level = 0
access-log = /var/log/kannel/access.log
dlr-storage = internal
store-type = spool
store-location = /var/spool/kannel/

group = smsbox
bearerbox-host = localhost
smsbox-id = APPM-smsbox
log-file = /var/log/kannel/smsbox.log
log-level = 0
sendsms-port = 13013

group = smsc
smsc = at
smsc-id = APPM-smsc
#log-file = /var/log/kannel/smsc_at.log
#log-level = 0
modemtype = auto
device = /dev/ttyS0
connect-allow-ip = 127.0.0.1
speed = 115200
sim-buffering = true
unified-prefix = "+7"
sms-center = "+7MMMXXXXXXX"

group = smsbox-route
smsbox-id = APPM-smsbox
smsc-id = APPM-smsc

group = modems
id = SIEMENS MC35i
name = "Siemens_MC35i"
detect-string = "SIEMENS"
detect-string2 = "MC35i"
init-string = "AT+CNMI=1,2,0,1,1"
enable-hwhs = "AT\\Q3"
need-sleep = true
message-storage = sm

group = sendsms-user
username = ""
password = ""
default-sender = +7MMMXXXXXXX

group = sms-service
keyword = default
text = "No service specified"
catch-all = true

Any help would be greatly appreciated!

Best regards,
Alexander Gubanov.

Reply via email to