1- try to setup latest kannel bcz 1.4.3 is too old. 2- share your full config. You dont need to setup Rx and Tx separately.
On Mon, Feb 6, 2012 at 12:25 PM, Shahid Bashir Ahmad < [email protected]> wrote: > This is our SMSc config. Everything is working fine but after one to two > hours connection goes dead and we needs to restart kannel. > > group = "smsc" > smsc = "smpp" > host = "*.*.*.*" > port = "5030" > smsc-username = "TEST" > smsc-password = "TEST" > system-type = "TEST" > smsc-id = "SMS-m" > transceiver-mode=true > group = sms-service > keyword = default > > -------------- Operator End Logs > > SMPPSERV_APP_BIND_FAIL Application has failed to bind as transceiver to > SMPP server system id FDITEL1 reason TRX connection limit exceeded node > ApplicationAccessGroup.SMPPServerGroup.smppServer**** > > SMPPSERV_APP_BIND_FAIL Application has failed to bind as transceiver > to SMPP server system id FDITEL1 reason TRX connection limit exceeded node > ApplicationAccessGroup.SMPPServerGroup.smppServer**** > > SMPPSERV_APP_BIND_FAIL Application has failed to bind as transceiver > to SMPP server system id FDITEL1 reason TRX connection limit exceeded node > **** > > ** ** > > **--------------- Our Logs** > > ** > ** > > 2012-01-19 03:36:02 [11343] [11] WARNING: SMPP: PDU NULL terminated string > (system_id) has no NULL.**** > > 2012-01-19 03:36:02 [11343] [11] DEBUG: SMPP[mobilink]: Got PDU:**** > > 2012-01-19 03:36:02 [11343] [11] DEBUG: SMPP PDU 0x8619000 dump:**** > > 2012-01-19 03:36:02 [11343] [11] DEBUG: type_name: bind_transceiver_resp > **** > > 2012-01-19 03:36:02 [11343] [11] DEBUG: command_id: 2147483657 = > 0x80000009**** > > 2012-01-19 03:36:02 [11343] [11] DEBUG: command_status: 13 = 0x0000000d* > *** > > 2012-01-19 03:36:02 [11343] [11] DEBUG: sequence_number: 153 = 0x00000099 > **** > > 2012-01-19 03:36:02 [11343] [11] DEBUG: system_id: NULL**** > > 2012-01-19 03:36:02 [11343] [11] DEBUG: SMPP PDU dump ends.**** > > 2012-01-19 03:36:02 [11343] [11] ERROR: SMPP[mobilink]: SMSC rejected > login to transmit, code 0x0000000d (Bind Failed).**** > > 2012-01-19 03:36:02 [11343] [11] ERROR: SMPP[mobilink]: I/O error or other > error. Re-connecting.**** > > 2012-01-19 03:36:02 [11343] [11] ERROR: SMPP[mobilink]: Couldn't connect > to SMS center (retrying in 10 seconds).**** > > 2012-01-19 03:36:12 [11343] [11] DEBUG: SMPP[mobilink]: Sending PDU:**** > > 2012-01-19 03:36:12 [11343] [11] DEBUG: SMPP PDU 0x8619000 dump:**** > > 2012-01-19 03:36:12 [11343] [11] DEBUG: type_name: bind_transceiver**** > > 2012-01-19 03:36:12 [11343] [11] DEBUG: command_id: 9 = 0x00000009**** > > 2012-01-19 03:36:12 [11343] [11] DEBUG: command_status: 0 = 0x00000000** > ** > > 2012-01-19 03:36:12 [11343] [11] DEBUG: sequence_number: 154 = 0x0000009a > **** > > 2012-01-19 03:36:12 [11343] [11] DEBUG: system_id: "TEST"**** > > 2012-01-19 03:36:12 [11343] [11] DEBUG: password: "TEST"**** > > 2012-01-19 03:36:12 [11343] [11] DEBUG: system_type: "TEST"**** > > 2012-01-19 03:36:12 [11343] [11] DEBUG: interface_version: 52 = > 0x00000034**** > > 2012-01-19 03:36:12 [11343] [11] DEBUG: addr_ton: 0 = 0x00000000**** > > 2012-01-19 03:36:12 [11343] [11] DEBUG: addr_npi: 0 = 0x00000000**** > > 2012-01-19 03:36:12 [11343] [11] DEBUG: address_range: NULL**** > > 2012-01-19 03:36:12 [11343] [11] DEBUG: SMPP PDU dump ends.**** > > 2012-01-19 03:36:12 [11343] [11] WARNING: SMPP: PDU NULL terminated string > (system_id) has no NULL.**** > > 2012-01-19 03:36:12 [11343] [11] DEBUG: SMPP[mobilink]: Got PDU:**** > > 2012-01-19 03:36:12 [11343] [11] DEBUG: SMPP PDU 0x8619000 dump:**** > > 2012-01-19 03:36:12 [11343] [11] DEBUG: type_name: bind_transceiver_resp > **** > > 2012-01-19 03:36:12 [11343] [11] DEBUG: command_id: 2147483657 = > 0x80000009**** > > 2012-01-19 03:36:12 [11343] [11] DEBUG: command_status: 15 = 0x0000000f* > *** > > 2012-01-19 03:36:12 [11343] [11] DEBUG: sequence_number: 154 = 0x0000009a > **** > > 2012-01-19 03:36:12 [11343] [11] DEBUG: system_id: NULL**** > > 2012-01-19 03:36:12 [11343] [11] DEBUG: SMPP PDU dump ends.**** > > 2012-01-19 03:36:12 [11343] [11] ERROR: SMPP[mobilink]: SMSC rejected > login to transmit, code 0x0000000f (Invalid System ID).**** > > 2012-01-19 03:36:12 [11343] [11] ERROR: SMPP[mobilink]: I/O error or other > error. Re-connecting.**** > > 2012-01-19 03:36:12 [11343] [11] DEBUG: Thread 11 > (gw/smsc/smsc_smpp.c:io_thread) terminates.**** > > 2012-01-19 03:40:48 [11343] [15] DEBUG: send_msg: sending msg to box: > <127.0.0.1>**** > > 2012-01-19 03:40:48 [11343] [15] DEBUG: boxc_sender: sent message to > <127.0.0.1>**** > > > > Operator sys they have allowed us one sessions and their mode is Trx. They > says that our kannel is creating more than one session at their end. I dont > know how to configure Tx and RX in cannel configuration. We are using > kannel 1.4.3 and smpp 3.4 > > > Regards, > Shahid > -- Regards, Abdul Basit | +92 32 1416 4196 | +92 30 0841 1445