Split your single bind into two separate binds (one with port only and one
with receive-port only) this will solve your problem.

On 3 July 2017 at 14:43, Dave <d...@eth0.ch> wrote:

> Hi all,
>
> does anyone knows this behaviour?
>
> The SMPP link is online for many days and after a reconnect (from the
> provider?) the link shows it is online but no messages are going through
> it. They are re-routed by Kannel internally through a different link.
>
> We experience this with two independent SMPP providers. However, it does
> not happen on every automatic reconnect. Could it be a configuration issue?
>
> group = smsc
> smsc = smpp
> smsc-id = <name1>
> allowed-smsc-id = >name1>;<name2>
> preferred-smsc-id = <name1>
> host = <ip>
> port = 2775
> receive-port = 2775
> smsc-username = <user>
> smsc-password = <pass>
> system-type = "DIR"
> throughput = 10
> dest-addr-ton = 2
> dest-addr-npi = 1
> bind-addr-ton = 1
> bind-addr-npi = 1
>
>
> group = smsc
> smsc = smpp
> smsc-id = <name2>
> allowed-smsc-id = <name2>;<name1>
> preferred-smsc-id = <name2>
> host = <ip>
> port = 2775
> receive-port = 2775
> smsc-username = <user>
> smsc-password = <pass>
> system-type = "CMT"
> throughput = 10
>
>
> Thanks for input, David.
>
>


-- 
Donald Jackson
http://www.ddj.co.za

Reply via email to