Hans, Sorry I missed out responding to this mail. At any time, only the active controller Reads the pssv_spcn_list file and Standby controller gets populated with configuration info by Active controller using MBCSv.
If switchover/Failover happens Because Standby already has information, it will proceed to provide service. In a scenario where we are second time rebooting (power on), and we have a scenario where previous standby Needs to be active, then it reads from the it's pssv_spcn_list (currently XML) and builds the system. This is how we envisioned. Are you facing any problem with this behaviour? Regards Murthy > -----Original Message----- > From: [EMAIL PROTECTED] > [mailto:[EMAIL PROTECTED] On Behalf Of Hans Feldt > Sent: Tuesday, October 16, 2007 5:21 PM > To: [email protected] > Subject: [Users] pssv_spcn_list attributes > > According to the controller rpm spec file, pssv_spcn_list is > persistent but not shared. Is that correct? According the expected behavious, this is correct. > > What happens e.g. when two controller are started (cold/power > on) with enough time between them to allow the first > controller to write 'PSS' to this file. From what source will > the second controller then boot XML or PSS? See response above. > > Regards, > Hans > _______________________________________________ > Users mailing list > [email protected] > http://list.opensaf.org/maillist/listinfo/users > _______________________________________________ Users mailing list [email protected] http://list.opensaf.org/maillist/listinfo/users