On 11/11/2011 01:17 PM, Craig White wrote: > On Fri, 2011-11-11 at 11:11 +0000, Gary Stainburn wrote: >> Hi folks. >> >> I'm using the built in hardware RAID on my server and have had to swap out >> one >> of the mirrored drives. Are there any utilities / methods of monitoring the >> hardware RAID while it rebuilds the mirror? > ---- > that would necessarily have to come from the hardware vendor > > Craig
If it's a serveraid card then some of the RAID status information is available via ipmi. The ipmi-sensors command (part of freeipmi) should be able to display drive status and overall RAID error status. If you don't mind using the vendor's proprietary tools then either IBM's ServeRAID manager or Adaptec's own raid management tool should work with these cards. Regards, Bryn. -- users mailing list [email protected] To unsubscribe or change subscription options: https://admin.fedoraproject.org/mailman/listinfo/users Guidelines: http://fedoraproject.org/wiki/Mailing_list_guidelines