Zaid can speak better than I can, but my experience has been that it does a refreshObject on the root upon initial checkin. And upon a preset interval.
On Wed, Jan 14, 2015 at 12:10 PM, Manny Veloso <[email protected]> wrote: > Presets live in mongo, in the presets collection. You can actually > generate presets directly in mongo. > > Question: I haven’t looked (and my instance is down right now), but does > GenieACs do that refreshObject on every inform? > -- > Manny Veloso > Sr. Solutions Engineer > Smartrg.com > > From: Christopher Chance <[email protected]> > Reply-To: Community support for GenieACS users <[email protected]> > Date: Wednesday, January 14, 2015 at 12:46 PM > To: Community support for GenieACS users <[email protected]> > Subject: RE: Presets... > > Ok just checking so even if after I setup a preset I never ever go back > to the GUI, genieacs-cwmp will still be using the presets that are setup in > genieacs-gui. > > > > The thing that has me a bit confused is because they’re completely > separate projects, I mean if you weren’t to install the gui and just use > the system via the NBI API, theres no “config” for presets in the genieacs > project. Which is where I am confused at. :S > > > > *From:* Users [mailto:[email protected] > <[email protected]>] *On Behalf Of *Dan Morphis > *Sent:* Wednesday, January 14, 2015 4:44 PM > *To:* Community support for GenieACS users > *Subject:* Re: Presets... > > > > Here is how presets work. Say you have a preset setting the > InternetGatewayDevice.ManagementServer.PeriodicInformInterval to 30 > seconds. When the CPE first contacts GenieACS, it sends a few bits of > information about itself. The next thing Genie does is send a > refreshObject: "", which refreshes the entire object model. When the CPE > sends the data back to genie, it then compares the values it got back to > what the preset is. > > > > If the value from the CPE for > InternetGatewayDevice.ManagementServer.PeriodicInformInterval is not 30, > then GenieACS will send a setParameterValue for > InternetGatewayDevice.ManagementServer.PeriodicInformInterval: 30. > > > > If you tell GenieACS to set > the InternetGatewayDevice.ManagementServer.PeriodicInformInterval on a CPE > to say 31 seconds. Genie will tell the CPE to set it to 31 seconds. Then, > Genie will tell the CPE to set it back to 30. Ask me how I know :). > > > > To answer the other part of your question, the GUI is getting/setting the > presets in GenieACS. Not the other way around. > > > > Custom commands allow you to do something special for your CPE. Things > that you might not be able to do via TR[069|098|etc]. > > > > -dan > > > > On Wed, Jan 14, 2015 at 11:31 AM, Christopher Chance < > [email protected]> wrote: > > I know what presets do if condition = met then configurations = happen > > > > But isn’t the presets part of the GUI Portion of genieacs? Wouldn’t it > have to be part of the genieacs package to perform the precondition check > on each inform? Or is the genieacs reaching across to the genieacs-gui > package to check the presets? > > > > Or are presets only working when a device is opened in the genieacs-gui > (which seems counter intuitive to what the presets are supposed to be > doing). > > > > That all said how do the presets compare to the “custom-commands” on the > genieacs side of things? (I mean I see theirs a greenpacket custom that > appears to check/mess with the frequencies via telnet, but why not just do > that via a preset through tr69?. > > > > Am I missing something? > > > > Chris > > > _______________________________________________ > Users mailing list > [email protected] > http://lists.genieacs.com/mailman/listinfo/users > > > > > > _______________________________________________ > Users mailing list > [email protected] > http://lists.genieacs.com/mailman/listinfo/users > >
_______________________________________________ Users mailing list [email protected] http://lists.genieacs.com/mailman/listinfo/users