On Sun, Aug 30, 2015, at 10:14 AM, Martin wrote: > I've just installed, connect the modem first, and get the following > error. Have you any idea what is wrong? > > 30 Aug 09:12:54 - 9C9726-MediaAccess%20TG588v-CP1402CZE4K: Inform (1 > BOOT); retry count 3 30 Aug 09:12:54 - 9C9726-MediaAccess%20TG588v- > CP1402CZE4K: Started task refreshObject(55e2aa37678212040743f651) > util.error: Use console.error instead 2015-08-30T07:13:23.309Z - > Error: PCDATA invalid Char value 2 > > at Error (native) at Object.module.exports.fromXml > (/opt/genieacs/node_modules/libxmljs/lib/document.js:120:21) at > Object.exports.request (/opt/genieacs/lib/soap.js:373:20) at > /opt/genieacs/lib/cwmp.js:642:26 at > /opt/genieacs/lib/cwmp.js:579:12 at bound (domain.js:254:14) at > runBound (domain.js:267:12) at try_callback > (/opt/genieacs/node_modules/redis/index.js:592:9) at > RedisClient.return_reply > (/opt/genieacs/node_modules/redis/index.js:685:13) at > HiredisReplyParser.<anonymous> > (/opt/genieacs/node_modules/redis/index.js:321:14) > > 30 Aug 09:13:23 - Worker 1950 died (null) 30 Aug 09:13:23 - Worker > 1992 listening to 0.0.0.0:7547
Looks like the device is sending invalid XML data. Try setting "XML_PARSE_RECOVER" option to true in config.json. That option will make XML parsing a bit more forgiving and can sometimes help with such issues. Zaid
_______________________________________________ Users mailing list [email protected] http://lists.genieacs.com/mailman/listinfo/users