Hi,

I had a problem related with the format of boolean parameters (I got 9002 and 9007 responses from ONTs): HG8245 and HG8245T only accept {0, 1} values but GenieACS uses {true, false} values; I got to overcome this problem by forcing GenieACS to use {0, 1} instead of {true false}.

This is what we did (the following code may be an old version so it may not be useful anymore):

https://github.com/zaidka/genieacs/blob/master/lib/soap.coffee
    Original code (near to line 160):

||(...)| for i in methodRequest.parameterList pvs = paramList.node('ParameterValueStruct') pvs.node('Name').text(i[0]) /*v = pvs.node('Value') v.text(i[1])*/ (...) |

    Modified code

||(...)| for i in methodRequest.parameterList pvs = paramList.node('ParameterValueStruct') pvs.node('Name').text(i[0]) /*v = pvs.node('Value') v.text(i[1])**v.text(1) if i[1] "true" v.text(0) if i[1] "false" */||(...)|


I hope this will help you.

P.D.: Later onI had a problem with certain parameters that prevented the ONTs to create WAN objects. We need 3 WAN interfaces; I configured the ONTs in 3 steps: I had the error on the 1st step. It was something about /RPC AddObject ...whitelist.//*0*//.List/, which would be rejected by the ONTs... the truth is that I am not sure if this was the reason why WAN objects were not created -all this happened several moths ago-, but I could not solve it, so I left GenieACS :/ ... for now

El 02/12/2015 a las 11:05, [email protected] escribió:
Send Users mailing list submissions to
        [email protected]

To subscribe or unsubscribe via the World Wide Web, visit
        http://lists.genieacs.com/mailman/listinfo/users
or, via email, send a message with subject or body 'help' to
        [email protected]

You can reach the person managing the list at
        [email protected]

When replying, please edit your Subject line so it is more specific
than "Re: Contents of Users digest..."


Today's Topics:

    1. Re: Huawei HG8245 <FaultCode> 9002 (Ivan Revyakin)
    2. Re: Huawei HG8245 <FaultCode> 9002 (Agust?n Bertamoni)
    3. Re: Parameters doesn't show up (Sergio Fern?ndez)


----------------------------------------------------------------------

Message: 1
Date: Tue, 1 Dec 2015 22:22:11 +0300
From: Ivan Revyakin <[email protected]>
To: Community support for GenieACS users <[email protected]>
Subject: Re: Huawei HG8245 <FaultCode> 9002
Message-ID:
        <CAO7cRBLUXKjstcN_9NOyvn+QZ=qdqxyad2oyqqtj6h_czxe...@mail.gmail.com>
Content-Type: text/plain; charset="utf-8"

Hello Agustin,

Yes, HG8245H works fine, but HG8245 is not HG8245H, it's another generation
of this ONT.
I guess you right -- this is device related issue. The Fault Code rises all
time.

    >> Device internal log has more information of this issue?
Could you help me how it possible to do? Which CLI commands should be used?

Thanks

2015-12-01 19:56 GMT+03:00 Agust?n Bertamoni <[email protected]>:

Ivan
Seems to be device related issue, we are testing GenieACS with HG8245H
and works ok.
Few questions: -always fails in GetParameterValues? with the sames
attributes?, Device internal log has more information of this issue? (via
web interface can access to tr69 logs)
I hope I've helped
BR
STECHS - Ing. Agustin Bertamoni
M?vil: (+54911) 62183226
Skype: abertamoni-stechs
Av. Boyac? 372 Piso 4? Oficina 401 (C1406BHF)
Buenos Aires, Argentina

On Tue, Dec 1, 2015 at 9:00 AM, Ivan Revyakin <[email protected]> wrote:

Hello.

I have two devices:

    - Huawei HG8245*H*
    - Huawei HG8245

HG8245*H* works good with GenieACS, but HG8245 does not. HG8245 returns
9002 Code (Fault Code) in the one of replays.
Capture files (*.pcap) for these two devices are here:
https://yadi.sk/d/tfrCoLIakschm

    - In "HG8245_fault.pcap" file Fault Code can be found in packet #339.
    - "HG8245H_Ok.pcap" file is good with no errors.

Can anyone help me why HG8245 returns Fault?


The version of HG8245 is V1R006C01S201
The version of HG8245*H* is V3R013C10S108
The version of GenieACS is 1.0 (git clone
https://github.com/zaidka/genieacs.git --branch v1.0)

--
Ivan


_______________________________________________
Users mailing list
[email protected]
http://lists.genieacs.com/mailman/listinfo/users


_______________________________________________
Users mailing list
[email protected]
http://lists.genieacs.com/mailman/listinfo/users




--
---------------------------------
*Pablo García Delgado *
Ingeniería



T: +34 955 337 633
F: +34 955 337 632
M: +34 620 092 674

www.magtel.es <http://www.magtel.es>
Polígono aeronáutico Aerópolis
Calle Juan Olivert, 11
41309, La Rinconada (Sevilla)
_______________________________________________
Users mailing list
[email protected]
http://lists.genieacs.com/mailman/listinfo/users