Hello Alfred,

create a refreshObject task for the specific parameter and make sure to do a connection request:

https://github.com/genieacs/genieacs/wiki/API-Reference#post-devicesdevice_idtasksconnection_request

Then query the database to get the current value of the parameter:

https://github.com/genieacs/genieacs/wiki/API-Reference#examples

(Example 5)

Greetings,
Oliver

Am 22.01.2018 02:07, schrieb Alfred George:
Hello Dan,
can you help me with this api. What is the API for this.

A.G

FROM: Users [mailto:[email protected]] ON BEHALF OF Dan
Morphis
SENT: Tuesday, January 9, 2018 8:44 AM
TO: Community support for GenieACS users <[email protected]>
SUBJECT: Re: Query a device for a specific parameter

No. Every time a CPE does an inform (etc), the ACS will run any
provision scripts and presets. When that happens, if any parameters
are stale (last update time is less then the time you specify), then
the parameter will be refreshed.

You can use the API and some code to manually refresh a parameter
every 30 seconds.

-dan

On Mon, Jan 8, 2018 at 2:19 AM, <[email protected]> wrote:

Is it possible to query a device from genieacs to refresh a specific
parameter more frequently than the periodic inform?

For example, my periodic inform is 5 minutes, but I want to get the
RSRP every 30 seconds.  Can I do this?

Thanks

_______________________________________________
Users mailing list
[email protected]
http://lists.genieacs.com/mailman/listinfo/users
_______________________________________________
Users mailing list
[email protected]
http://lists.genieacs.com/mailman/listinfo/users

_______________________________________________
Users mailing list
[email protected]
http://lists.genieacs.com/mailman/listinfo/users

Reply via email to