Hello Christian, Thanks for your reply, by the way, I would like to have a desktop computer where I can run Sculpt without any error, which computer you suggest for that? I am not a big expert of PCI ports.
Regards, Edoardo Mantovani Il giorno mar 23 feb 2021 alle ore 06:39 Christian Helmuth <[email protected]> ha scritto: > > Hello Edoardo, > > your SATA PCI devices seem to use a programming interface that's not > AHCI compatible. > > <device bdf="0:1f.2" vendor_id="0x8086" device_id="0x3b2e" > class_code="0x1018a" bridge="no" cap="0x1" cap="0x13"/> > <device bdf="0:1f.5" vendor_id="0x8086" device_id="0x3b2d" > class_code="0x10185" bridge="no" cap="0x1" cap="0x13"/> > > For AHCI compatibility the class code has to be 0x0106xx. Your devices > use 0101xx which is "IDE interface" [1] [2] [3] and Genode does not > support this. > > [1] https://pci-ids.ucw.cz/read/PD/01/01 > [2] https://pci-ids.ucw.cz/read/PD/01/01/8a > [3] https://pci-ids.ucw.cz/read/PD/01/01/85 > > Regards > -- > Christian Helmuth > Genode Labs > > https://www.genode-labs.com/ · https://genode.org/ > https://twitter.com/GenodeLabs · /ˈdʒiː.nəʊd/ > > Genode Labs GmbH · Amtsgericht Dresden · HRB 28424 · Sitz Dresden > Geschäftsführer: Dr.-Ing. Norman Feske, Christian Helmuth > > _______________________________________________ > Genode users mailing list > [email protected] > https://lists.genode.org/listinfo/users -- Edoardo Mantovani Independent security researcher email: [email protected] Urbino, Italy _______________________________________________ Genode users mailing list [email protected] https://lists.genode.org/listinfo/users