Hello Michael, On Fri, Mar 05, 2021 at 12:54:14PM +0100, Michael Grunditz wrote: > In message <[email protected]> > Stefan Kalkowski <[email protected]> wrote: > > > Hello Michael, > > > On Wed, Mar 03, 2021 at 11:22:33PM +0100, Michael Grunditz wrote: > >> Hi, > >> > >> I have a kernel call that starts RISC OS, and uses psci. I wonder , where > >> should I put that very aarch64 dependent code. I somehow need to be able > >> to call it from userspace. > >> > >> Regarding kernel calls in general , what is the best way of calling them? > >> Right now I do "MOV x0,#number ; SVC" , probably not very Genode style! :) > > > Actually, there is already support for what you are looking for, I > > think. As far as I understood it correctly, you want to wake up the > > Cortex-M4 (side-) processor, after you've prepared RiscOS to run on top of > > it? > > > RISC OS doesn't run on a M4, it is a desktop OS. Even if it is very light > and no overhead, it needs a proper cpu
Ah ok sorry, I've misunderstood that. > > > > Of course, you should not just add a system call that can be executed > > by every component to do something like this ;-). But we already had > > similar needs, when doing power control inside of the platform driver > > for i.MX 8M. There are some GPC controls that are done by the ARM > > Trusted firmware. Therefore we extended a previously existent > > privilege to the so called "managing_system" privilege that can be > > given when creating a new PD resp. component. This privilege is > > typically given only to the platform driver. With it a component can > > do a "managing_system(State&)" call on its PD session. This call transfers > > registers (State == Cpu_state) to core, which on will do a "secure > > monitor call" with the given registers (at least on ARMv8). > > For further understanding, please grep for "managing_system" inside > > base and base-hw. > > I think that the startup call , and possible restart needs to be in a > driver. I think that what you did wrote is about that, but I need to > explore the sources to fully understand. I also need a interrupthandler > for the MU. I just poll the Message Unit now ,which is fine for serial > output from RISC OS. But I have started with a filing system, which > probably would be good if it was interrupt driven. Yet a lot to decide ... > > > > To sum it up, you could define a specific "Power_domain" for the M4 in > > the platform driver of your board, and then do the corresponding SMC > > call therein using the managing_system call. Your application doing > > the RiscOS loading just needs to acquire the device with the M4 > > Power_domain from the platform driver at the point where you want to > > power it, and release it again when you want to power it off. > > > This way, you will have a secure and sane integration of the M4 > > handling. > > Thanks! Can this Power_domain thing also work for A53? In general yes, I do not see what should stay against this. You still need an adapted version of the platform_driver for your specific setup, which implements the A53 Power_domain by using the "managing_system" so-to-say "SMC wrapper". Regards Stefan > > Michael > > _______________________________________________ > Genode users mailing list > [email protected] > https://lists.genode.org/listinfo/users -- Stefan Kalkowski Genode labs https://github.com/skalk | https://genode.org _______________________________________________ Genode users mailing list [email protected] https://lists.genode.org/listinfo/users