Michael Di Domenico <mdidomeni...@gmail.com> writes:

> It a freshly reformatted cluster
> converting from solaris to linux.  We also reset the bios settings
> with "load optimal defaults".

[Why?]

> Does anyone know which bios setting i
> changed to dump the BW?

Off-topic, and surely better on the Beowulf list, it's answered
somewhere in the OFED docs:  Make the MTRR setting `discrete' (under the
CPU parameters in the AMI BIOS versions with which I'm familiar).

I can't think of a suitable Ob-OMPI.