Hi,
Exactly it's two bonding interfaces working in active-standby mode.
Pozdrawiam
TomekC
On Fri, Jul 10, 2015 at 6:33 AM -0700, "Dan Houtz" <[email protected]> wrote:
Hi,
Is anyone currently doing redundant connectivity to bare metal servers? Our
initial thought was that we would do two top of rack QFX running MC-LAG so our
servers could run LACP to both of them however MC-LAG is not currently
supported with VXLAN (I'm told it's on the roadmap). I suspect virtual chassis
would allow us do to this but haven't tested and honestly we don't really want
to stack the switches. I guess the other potential option is to just drop both
of the server's nic ports in a VNI and not run any intelligence protocols
though this doesn't seem like the proper way to do it :)
Would definitely be interested in other people's experiences if this is being
done.
Thanks!Dan
_______________________________________________
Users mailing list
[email protected]
http://lists.opencontrail.org/mailman/listinfo/users_lists.opencontrail.org