Hi Chris,

[ID 261363 daemon.error] Error: Request packet had invalid CRC32.
[ID 900267 daemon.error] Client request was invalid, bailing out...

and the client would report

CHECK_NRPE: Received 0 bytes from daemon.  Check the remote server
logs for error messages.

Boxes running 06-18 could communicate with each other fine, though, as
could all the others

due to several user requests I recompiled the the NRPE packages, so that agent and plugin can send / receive network packets with a size of 8 kB. Obviously this not compatible to former versions.

As a quick workaround I could send you packages compiled for a packet size of 1 kB (as it was in the version 2009-05-17).

Greetings,

Juergen

--
Juergen Arndt
_______________________________________________
users mailing list
[email protected]
https://lists.opencsw.org/mailman/listinfo/users