(sorry: just repost to follow correct thread/subjet)

I just found another example from rfc3261 where an endpoint will use 5xx class answer:

12.2.2 UAS Behavior

Page 76:

   If the remote sequence number is empty, it MUST be set to the value
   of the sequence number in the CSeq header field value in the request.
   If the remote sequence number was not empty, but the sequence number
   of the request is lower than the remote sequence number, the request
   is out of order and MUST be rejected with a 500 (Server Internal
   Error) response.

Hope I convinced you!

tks,
Aymeric MOIZARD / ANTISIP
amsip - http://www.antisip.com
osip2 - http://www.osip.org
eXosip2 - http://savannah.nongnu.org/projects/exosip/


On Wed, 16 Jan 2008, Iñaki Baz Castillo wrote:

On Wednesday 16 January 2008 13:44:10 A.smith wrote:

If I try and use the whole example cfg (not just the route) I am recieving
an error like:

 0(23448) find_cmd_export_t: <lookup> not found
 0(23448) parse error (105,23-24): unknown command, missing loadmodule?

"lookup()" is defined in "registrar" module that you are not loading:
 http://www.openser.org/docs/modules/1.2.x/registrar.html#AEN342

--
Iñaki Baz Castillo
[EMAIL PROTECTED]

_______________________________________________
Users mailing list
Users@lists.openser.org
http://lists.openser.org/cgi-bin/mailman/listinfo/users
_______________________________________________
Users mailing list
Users@lists.openser.org
http://lists.openser.org/cgi-bin/mailman/listinfo/users

Reply via email to