Hi Denis,

From SIP point of view, the BYE must be sent to the contact URIs . I guess your contact is different than the layer3 IP because of some NAT presence, right ? if so, use fix_nated_contact() for INVITE and 200 OK, so that the received contact will be "fixed" with the layer3 IP, so the dialog module will use the contact with a useful info.

Regards,
Bogdan

Denis Putyato wrote:

Hello!

I am using dialog module for control of call duration.

When timeout of dialog expires I need Opensips send BYE not to caller and callee contact (which is stored during creation of dialog) but to IP address and port from which INVITE (caller) and 200 OK (callee) had been received.

Thank you for any help

------------------------------------------------------------------------

_______________________________________________
Users mailing list
[email protected]
http://lists.opensips.org/cgi-bin/mailman/listinfo/users


--
Bogdan-Andrei Iancu
OpenSIPS Event - expo, conf, social, bootcamp
2 - 4 February 2011, ITExpo, Miami,  USA
OpenSIPS solutions and "know-how"


_______________________________________________
Users mailing list
[email protected]
http://lists.opensips.org/cgi-bin/mailman/listinfo/users

Reply via email to