Hello,
The scenario you are describing is not possible because the TCP
connection has attached to it the actual SIP msg that has been read so
far. So if one worker receives EAGAIN, it will put the TCP connection
back on the IN reactor, and when the FD will be triggered again, another
worker will continue to read to the same SIP msg as the previous worker.
Regards,
Vlad Paiu
OpenSIPS Developer
On 12/05/2011 05:16 AM, dongwflj wrote:
Hi:
I am learning opensip2, it seems currently no support for epoll ET,
will we support it in future?
If we use ET, two TCP sip messages come to server, I think one worker
thread should read all but till EAGAIN, but during the worker thread
is reading, another new packet coming on the same connection, that
will trigger another worker thread start to read buffer, will it cause
the 2 worker thread read wrong data? How can we solve this kind of
problem? Thanks!
_______________________________________________
Users mailing list
[email protected]
http://lists.opensips.org/cgi-bin/mailman/listinfo/users
_______________________________________________
Users mailing list
[email protected]
http://lists.opensips.org/cgi-bin/mailman/listinfo/users